ABB S203P-Z40 — Miniature Circuit Breakers (MCB)

ABB S203P-Z40 MCB, 3P, 40A, Curve Z, 10kA, DIN Rail

MPNS203P-Z40

ABB S203P-Z40, 3-pole miniature circuit breaker, 40 A, Trip Curve Z, 277 VAC, 10 kA interrupting rating, DIN rail mount.

$59.69Ref. price · indicative, final on quote
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

S203P-Z40 — Specifications
ParameterValue
Amps40
TypeTrip Curve Z
Poles3
MountingDIN Rail
Volts AC277
Breaking capacity10 kA

Product details

Curve Z is the tightest standard trip curve, tripping between 2 and 3 times rated current (80–120 A for this unit), which makes it the right choice for protecting semiconductor circuits, PLC power supplies, and other sensitive electronic loads where a standard C-curve would let through too much energy before opening.

Three poles means it switches all phases simultaneously — required for three-phase sub-feeds or motor branch circuits where you need full disconnection. The 277 VAC phase-to-neutral rating matches 480Y/277 V wye systems, so it's a direct fit for North American commercial panels fed from a 480/277 V transformer.

Frequently asked questions

How do I get current pricing and availability for S203P-Z40?

Submit an RFQ through this listing. We source it to order and confirm availability and pricing at quote time.

What's the difference between S203P-Z40 and S203-D13?

The S203-D13 is a 10 A, Curve D breaker — same 3-pole DIN-rail footprint and 10 kA interrupt rating, but the trip curve is much slower (10–20× rated current). The Z40 is for sensitive electronic loads; the D13 is for motor or transformer inrush. They share the same physical dimensions and busbar pattern, so swapping one for the other on the same panel requires no rewiring — just verify the ampacity and trip coordination match the circuit.

What is S203P-Z40's listed amps?

40 A continuous rating.

What does Trip Curve Z mean?

Curve Z trips at 2 to 3 times rated current — for the 40 A unit, that's 80–120 A magnetic trip. It's the fastest standard curve, designed to protect semiconductor circuits and sensitive electronics where a C-curve would pass too much fault energy.

Will S203P-Z40 drop into a panel specified around S203-D13 without rewiring?

Yes — same 3-pole DIN-rail footprint, same busbar spacing. The swap is mechanical; just verify the 40 A rating and Curve Z trip characteristic match the circuit protection requirements.