Skip to main content
ABB S801S-K32 — 1-Pole MCB (DIN Rail)

ABB S801S-K32 MCB 1P K 32A, 50 kA

MPNS801S-K32

ABB S800S series, S801S-K32, 1-pole miniature circuit breaker, Trip Curve K, 32 A, 230 VAC, 50 kA interrupting rating, DIN rail mount.

StockContact for availability
Lead timeCall for availability wk
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Specifications

S801S-K32 — Specifications
ParameterValue
Amps32
TypeTrip Curve K
Poles1
MountingDIN Rail
Volts AC230
Breaking capacity50 kA

Product details

32 A, Curve K — built for motor and transformer circuits

The ABB S801S-K32 is a 1-pole miniature circuit breaker from the S800S series, rated at 32 A with a Trip Curve K characteristic. That curve is the one you reach for when the load draws a high inrush — motors, transformers, solenoid banks — where a B-curve would nuisance-trip on startup and a C-curve might still be borderline. The 50 kA interrupting rating at 230 VAC gives it the headroom to clear a hard fault without cascading upstream, which matters when this breaker sits in a distribution panel feeding a motor control center. Snaps onto standard DIN rail, so it integrates into any panel that already carries S800S or similar modular gear. Single-pole means it protects one phase; for three-phase motor feeds you'd stack three units with a common handle tie.

Frequently asked questions

Where can I buy S801S-K32 and how do I get a price?

The S801S-K32 is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

When sourcing S801S-K32, what's the closest functional second-source — S201MUC-K2?

The S201MUC-K2 is a 2 A, 1-pole, Curve K MCB on DIN rail — same curve family but a much lower amp rating. It won't drop in as a substitute for a 32 A circuit; the S801S-K32 is the correct part for the 32 A load.

What is S801S-K32's listed amps (32) on this component line?

The S801S-K32 is rated at 32 A continuous, with Trip Curve K for high-inrush loads like motors and transformers.

What is S801S-K32's listed type (Trip Curve K) on this component line?

Trip Curve K means the magnetic trip threshold is set to 8–12x In, designed to pass the inrush of motor and transformer loads without nuisance tripping.

Will S801S-K32 drop into a panel that was specified around S201MUC-K2 without rewiring?

Both mount on standard DIN rail, but the S801S-K32 is a 32 A breaker while the S201MUC-K2 is 2 A — the panel's wiring and upstream protection must be sized for 32 A, so a direct swap without rewiring is not possible.

What compliance documentation does this brand provide for S801S-K32 (RoHS, REACH, UL, IEC)?

ABB typically provides RoHS and REACH declarations, plus IEC/EN 60898-1 certification for the S800S series. Specific documentation is available on request with an RFQ.

MPN