Skip to main content
ABB S802S-K50 — 2-Pole MCB (DIN Rail)

S802S-K50 50A 2-Pole K-Curve MCB, 50 kA, DIN Rail

MPNS802S-K50

ABB S802S-K50, High Performance Miniature Circuit Breaker, 2 Pole, 50 Amp, Trip Curve K, 230 VAC, 50 kA interrupting rating, DIN Rail mount.

StockContact for availability
Lead timeCall for availability wk
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Specifications

S802S-K50 — Specifications
ParameterValue
Amps50
TypeTrip Curve K
Poles2
MountingDIN Rail
Volts AC230
Breaking capacity50 kA

Product details

What the ratings mean for fit

The S802S-K50 is a 2-pole miniature circuit breaker rated 50 A with a Trip Curve K characteristic, designed for DIN-rail mounting in distribution panels. The 50 kA interrupting rating at 230 VAC means it can safely clear a bolted fault up to that level without welding contacts or cascading upstream — essential for high-fault-capacity installations like industrial sub-distribution boards or MCC buckets where the available fault current exceeds standard 10 kA or 25 kA MCB ratings. Curve K trips magnetically between 8× and 12× rated current, which is faster than a D-curve on moderate overloads and avoids nuisance tripping on transformer inrush or motor starting currents that a B- or C-curve might catch. That makes it a common choice for protecting inductive loads — contactor coils, solenoid valves, small transformers — where the inrush spike is brief but high.

Panel integration note

Snap-on DIN rail mounting means it clips directly onto a 35 mm symmetrical rail inside the enclosure. The 2-pole width occupies two modular units (36 mm at 18 mm per pole), so factor that into the DIN-rail fill count when laying out the panel. No separate mounting hardware or busbar adapter needed for the rail itself.

Frequently asked questions

What is the S802S-K50 used for?

The S802S-K50 is a 2-pole, 50 A miniature circuit breaker with a Trip Curve K characteristic, used for overcurrent and short-circuit protection of inductive loads in industrial control panels and sub-distribution boards.

Where can I buy the S802S-K50?

The S802S-K50 is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

What does Trip Curve K mean on this breaker?

Trip Curve K means the magnetic trip operates between 8× and 12× rated current (400–600 A for this 50 A unit), making it suitable for inductive loads with moderate inrush such as transformers, contactors, and solenoid valves.

What is the interrupting rating of the S802S-K50?

The S802S-K50 has a 50 kA interrupting rating at 230 VAC, allowing it to safely clear high-fault currents in industrial installations.

MPN
S802S-K50