Skip to main content
ABB S802U-K100 — 2-Pole MCB (DIN Rail)

S802U-K100 MCB 2P K 100A, 25 kA

MPNS802U-K100

ABB S800 series, S802U-K100, 2-pole miniature circuit breaker, 100 A, Trip Curve K, 240 VAC, 25 kA interrupting rating, DIN rail mount.

$172.72Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

S802U-K100 — Specifications
ParameterValue
Amps100
TypeTrip Curve K
Poles2
MountingDIN Rail
Volts AC240
Breaking capacity25 kA

Product details

The S802U-K100 is a 2-pole miniature circuit breaker from the ABB S800 series, rated 100 A at 240 VAC with a Trip Curve K characteristic. That 100 A continuous rating and 25 kA interrupting capacity mean it handles high-current branch circuits — think large motor starters, welder feeds, or main distribution panels — where fault currents can hit serious levels. The K curve is the key: it holds through moderate inrush (motors, transformers) but trips fast on a hard short, tighter than a D curve but looser than a C. For a 100 A motor load, that's the difference between nuisance trips on startup and actual protection.

Panel integration

Snaps onto standard DIN rail — no special mounting hardware needed. Two-pole footprint keeps panel space tight; at 100 A, the S800 series uses a wider module than the S200 line, so check your enclosure fill factor before committing the layout. Rated for 240 VAC, so it's a straight fit into North American 120/240 V split-phase or European 230/400 V distribution panels on the line-to-neutral leg.

Frequently asked questions

What is S802U-K100 used for?

It's a 2-pole miniature circuit breaker rated 100 A with Trip Curve K, designed for motor and transformer branch circuits where moderate inrush tolerance is needed, paired with a 25 kA interrupting capacity for high-fault-current distribution panels.

Where can I buy S802U-K100?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm commitment.

Will S802U-K100 drop into a panel specified around S202P-K32 without rewiring?

No — the S202P-K32 is a 32 A, 2-pole, K-curve breaker from the S200 series with a 10 kA interrupting rating at 277 VAC, while the S802U-K100 is a 100 A, 25 kA device from the S800 series. The S800 series uses a wider module footprint, so it won't fit the same DIN-rail slot without panel rework and busbar changes.

MPN