ABB XT1NU3050AFF000XXX — Molded Case Circuit Breakers (MCCB)

ABB XT1NU3050AFF000XXX Tmax XT1N Frame, 125 A, 3-Pole, Therm

MPNXT1NU3050AFF000XXX

ABB Tmax XT1N frame, XT1NU3050AFF000XXX, 125 A, 3-pole molded case circuit breaker with thermal-magnetic fixed trip, frame mount, front flat terminals.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Specifications

XT1NU3050AFF000XXX — Specifications
ParameterValue
Amps125
Poles3
MountingFrame

Product details

The ABB XT1NU3050AFF000XXX is a Tmax XT1N frame molded case circuit breaker rated 125 A, 3-pole, with a fixed thermal-magnetic trip unit adjustable 50-500 A. Frame-mounted with front flat terminals — this is the standard distribution and motor branch-circuit protection package for panel builders and plant electricians. The 125 A rating means it handles feeder circuits and larger motor loads in that range; the fixed thermal-magnetic trip gives you a reliable, no-nonsense overcurrent and short-circuit response curve without electronic adjustment complexity.

What the Ratings Mean for Fit

125 A continuous current at 40 °C ambient is the headline number — that's the breaker's uninterrupted load capability before the thermal element starts to track. For a 3-pole configuration on a 480Y/277 V or 208Y/120 V system, that covers feeder circuits, large motor branch circuits, and distribution subpanels. The fixed thermal-magnetic trip (50-500 A range on the magnetic pickup) means the short-circuit response is set at the factory; no field-adjustable electronic trip unit to calibrate. That's fine for standard motor starting and distribution duty where you don't need curve shaping. Frame mounting means it bolts into a switchboard or panel chassis — not a DIN-rail snap-in, so plan your enclosure cutouts and bus connections accordingly.

Deployment Context

Frame-mounted breakers like this one land in industrial switchboards, motor control centers, and distribution panels. The front flat terminals accept standard bus bar or cable lugs — no special adapter kit needed. For a panel OEM or plant electrician, that means straightforward bus connections and a clean layout. The XT1N frame is compact for its rating class, so it fits in tighter panel sections without sacrificing interrupting capacity.

Frequently asked questions

What is the closest alternative to XT1NU3050AFF000XXX in the Tmax family?

Within the Tmax XT1 frame, the primary alternative would be a version with a different trip type or terminal configuration — for example, an electronic trip unit or rear-connect terminals. The frame size, pole count, and continuous current rating are the main fit parameters; if you need the same 125 A, 3-pole, fixed thermal-magnetic trip with front flat terminals, this is the direct order code. No pin-compatible drop-in exists that changes only the trip curve without also changing the order code.

Where can I buy XT1NU3050AFF000XXX?

Sourced to order against an RFQ through independent industrial-automation distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead-time commitment.

MPN
XT1NU3050AFF000XXX