ABB, XT5N Series, Molded Case Circuit Breaker, XT5NU340AEFF000XXX, 400 A, 600 V AC/DC, 3-Pole, Ekip Dip LS/I, UL/CSA.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

XT5NU340AEFF000XXX — Specifications
ParameterValue
Amps400
TypeBreaker; Molded Case
Poles3
Volts AC600
Volts DC600

Product details

400 A Molded Case Breaker with Ekip Dip LS/I Protection

The ABB XT5NU340AEFF000XXX is a 400 A, 3-pole molded case circuit breaker (MCCB) from the XT5N frame, rated for 600 V AC and 600 V DC. It carries the Ekip Dip LS/I electronic trip unit, which gives you adjustable long-time (L) and short-time (S) pickup and delay, plus fixed instantaneous (I) protection. The 400 A frame is sized for main feeder or large motor branch protection where you need selectivity downstream. For a commissioning engineer verifying the protection scheme: the LS/I curve means you can coordinate the breaker with downstream devices by setting the S delay — a common requirement on a panel fed by a transformer or generator. The 600 V DC rating covers battery banks or UPS outputs, though verify the DC polarity marking on the terminals before energizing.

Duty and Deployment Context

The XT5N frame mounts in a standard switchboard or panel enclosure on a bolted bus connection — no DIN-rail adapter for this frame class. The 400 A continuous rating and 600 V AC/DC withstand let it serve as a main disconnect on a 600 V distribution panel. For a field-service tech isolating a fault: the breaker's rotary handle mechanism provides visible indication of the contact position. The Ekip Dip unit stores the last-trip cause (L, S, or I) on the LCD, which cuts down troubleshooting time on a downstream short or overload event.

Frequently asked questions

What are the key ratings of the XT5NU340AEFF000XXX?

It is a 400 A, 3-pole molded case breaker rated for 600 V AC and 600 V DC, with an Ekip Dip LS/I electronic trip unit. The UL and CSA listings cover North American installations.

Where can I buy the XT5NU340AEFF000XXX?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at the time of your quote request — contact our desk with your quantity and target delivery window.

What does the Ekip Dip LS/I trip unit provide?

The LS/I designation means adjustable long-time (L) and short-time (S) protection with fixed instantaneous (I) pickup. The S delay setting allows selective coordination with downstream breakers, which is essential for maintaining power to healthy circuits during a fault.