ABB 1SFA895006R7020

ABB PST60 Soft Starter 1SFA895006R7020, 60 A In-Line, 105 A

MPN 1SFA895006R7020
Obsolete

ABB PST60 series soft starter, order code 1SFA895006R7020, 60 A in-line / 105 A inside-delta, 400-690 V AC main circuit, built-in electronic overload, 0-120 s ramp time, 100-250 V AC control supply.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

1SFA895006R7020 specifications
ParameterValue
Terminal typeScrew Terminal
VoltageMain Circuit 400 ... 690 V AC
Frequency50/60 Hz
ProtocolFiledBusPlug(Standard)
Temp operating max50 °C
Temp operating min0 °C

Product details

Rated for the motor load, not just the nameplate

The ABB PST60 soft starter 1SFA895006R7020 carries two distinct current ratings that govern how it connects to the motor. In-line connection is rated 60 A — that is the current through the starter when wired directly in the supply lines. Inside-delta connection (switches in the delta legs) is rated 105 A, which lets it start a 55 kW motor at 400 V. The 60 A in-line figure is the one to match against the motor FLA for a standard installation; the 105 A delta figure applies only when the starter is wired per the inside-delta topology, which reduces the current per phase through the thyristors. Main circuit voltage range is 400 to 690 V AC, covering standard European 400 V three-phase and 690 V industrial networks. The control supply is 100-250 V AC, so it accepts a common panel control transformer without a separate DC supply. Built-in electronic overload protection eliminates the need for a separate overload relay in most applications — the starter itself handles thermal protection based on motor current, not just a bimetallic curve.

Ramp and start parameters

Ramp time is adjustable from 0 to 120 seconds, giving a wide window for soft-starting conveyors, pumps, or fans. Initial voltage during start is settable between 30 and 70 % of line voltage, and the step-down voltage special ramp can be set from 100 down to 30 %. Starting capacity is 3xIe for 15 seconds, which handles typical high-inertia loads without nuisance tripping. The current limit function is adjustable from 1.5 to 7 times the set Ie, so you can clamp the inrush to a multiple of the motor FLA.

Signals and integration

The starter provides four signal relays: run, fault, by-pass, and overload. These give the PLC or DCS discrete feedback for each state without needing auxiliary contactors. Analog output is 0-10 V, usable for a panel meter or drive speed reference. Communication is via a standard FieldBusPlug — the starter accepts a fieldbus adapter module, not a built-in protocol stack. Screw terminals on the control circuit with a tightening torque of 0.5 N·m. Main circuit connecting capacity is rigid 1 x 10 to 95 mm², sized for the 60-105 A range.

MPN
1SFA895006R7020