ABB F204 B-125/0,5

ABB F204 B-125/0,5 RCCB, 125 A, 500 mA, Type B, 4-Pole

MPN F204 B-125/0,5

ABB F204 B-125/0,5 residual current circuit breaker, 4-pole, 125 A, 500 mA type B, 230/400 V AC, DIN-rail mount.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

F204 B-125/0,5 specifications
ParameterValue
Product typeResidual current circuit breaker
Voltage230/400 V AC
Insulation voltage ui500 V
Current125 A
IP ratingIP2X
MountingDIN Rail
Temp operating max40 °C
Temp operating min-25 °C
Pollution degree2
Weight0.5 kg
Dimensions72 x 85 x 69

Product details

The ABB F204 B-125/0,5 is a 4-pole residual current circuit breaker (RCCB) rated for 125 A continuous current and 500 mA residual trip threshold. It is a Type B device, meaning it detects smooth DC fault currents as well as AC and pulsed DC — essential for drives, UPS systems, and PV inverters where pure sine-wave residual currents can blind a standard AC or A-type RCCB. Rated 230/400 V AC, it fits three-phase four-wire networks (TN-S, TT) common in European industrial panels.

The 125 A rated current (In) is the continuous load the RCCB can carry without overheating. For a 125 A frame, expect the upstream breaker to be sized at or below this — coordination studies typically target 80 % loading for thermal headroom in a 40 °C ambient. The 500 mA residual current is a high-threshold device — not for personnel protection (which needs 30 mA or less), but for equipment protection or fire prevention on large feeders where nuisance tripping from cable capacitance would plague a lower-sensitivity unit. Type B detection covers frequencies up to 1 kHz or more, so it handles the mixed-frequency leakage from VFD output cables without false trips. Pollution degree 2 means the RCCB is rated for non-conductive pollution that might become temporarily conductive due to condensation — typical of a clean industrial panel, not a washdown zone. The IP2X housing protects against fingers (12 mm probe), not water ingress. Power loss per pole is 7.5 W at rated conditions, so the total dissipation across four poles is 30 W. That heat must be considered in a crowded DIN-rail enclosure — adjacent devices may need derating or spacing.

MPN