Siemens 3RT1054-1PP35-0SW0

Siemens 3RT1054-1PP35-0SW0 SIRIUS Power Contactor, Size S6,

MPN 3RT1054-1PP35-0SW0

Siemens SIRIUS, power contactor, size S6, 200-277 V AC coil, screw-type terminals, 170 mm depth, 140 mm width, 172 mm height.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

3RT1054-1PP35-0SW0 specifications
ParameterValue
Mountingscrew fixing
Depth170 mm
Width140 mm
Height172 mm
Arcing time10 ... 15 ms

Product details

The 170 mm depth and 140 mm width fit standard enclosure layouts, but the 172 mm height is worth checking against your panel's internal clearance — it's taller than many S6 frames.

The coil pulls in at 80-90 ms on both AC and DC supplies, with dropout below 0.8x rated voltage. That's a standard operating speed for a contactor this size — fast enough for most motor starts, not so fast that it causes nuisance dropouts on a sagging line. Arcing time runs 10-15 ms, which matters for contactor life on high-inrush loads like motors or transformers. Switching frequency limits are given per duty class: 1,000 cycles/hour for AC-3 and AC-3e (standard motor starting), 800 for AC-1 (resistive), 400 for AC-2 (slip-ring motors), and only 130 for AC-4 (plugging/inching). If your application requires frequent reversing or jogging, the AC-4 limit of 130 ops/hour is the binding constraint — don't spec this contactor for a high-cycle reversing conveyor without checking that duty cycle. Auxiliary contact ratings cover the common control voltages: 10 A at 24 V, 6 A at 230 V, 3 A at 400 V, and 0.3 A at 220 V DC. The DC switching capacity drops sharply with voltage — at 220 V DC it's only 0.3 A, so verify your DC control loads don't exceed that curve. The 60 °C ceiling is typical for a panel-mounted contactor; if your enclosure sees higher ambient (near a furnace or in direct sun), you'll need to derate or move to a ventilated cabinet.

Fastened by screw fixing, not snap-on DIN rail. That means a drilled backplate and threaded inserts — plan for that in the panel layout. The 20 mm forward clearance is the one that catches people out; make sure the enclosure door or busbar system leaves that gap. Main circuit wiring accepts solid conductors 2x (0.5-1.5 mm²), 2x (0.75-2.5 mm²), or max 2x (0.75-4 mm²). Stranded cable goes up to 1x 50 or 1x 70 mm². That's a wide range — fine for both control wiring (smaller gauges) and power feeds (larger gauges). Use ferrules on stranded wire for reliable screw-terminal connections.

MPN
3RT1054-1PP35-0SW0