Skip to main content
Siemens 3RT2023-4AP60

Siemens 3RT2023-4AP60 SIRIUS Power Contactor, S0 Frame, 45 m

MPN 3RT2023-4AP60

Siemens SIRIUS power contactor, 3RT2023-4AP60, S0 frame size, 45 mm width, screw and snap-on DIN rail mounting, auxiliary switch included.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

3RT2023-4AP60 specifications
ParameterValue
Depth97 mm
Width45 mm
Height85 mm
Arcing time10 ... 10 ms

Product details

At 45 mm wide and 97 mm deep, it occupies one standard 45 mm module slot on the rail — a dimension that matters when you're laying out a crowded enclosure and need to know exactly how much DIN space each contactor consumes. The contactor includes an integrated auxiliary switch, so you don't need to add a separate side-mount block for basic status feedback or interlocking in the control circuit.

The switching frequency tells you how hard you can cycle this contactor in continuous operation: 1,000 operations per hour for AC-1 (resistive), AC-2 (slip-ring motor), AC-3 (squirrel-cage motor starting), and AC-3e (enhanced AC-3) duty classes. For AC-4 duty — plugging and inching — the rate drops to 300 operations per hour, because the make-and-break on locked-rotor current generates more heat in the arc chamber. The auxiliary contact ratings span the common control voltages you'll find in a panel: 10 A at 24 V, 2 A at 48 V or 60 V, 1 A at 110 V, 0.9 A at 125 V, 0.3 A at 220 V, 3 A at 400 V, 0.6 A at 440 V, 7.6 A at 480 V, and 2 A at 500 V. These are the current-carrying limits for the auxiliary circuit — useful when you're feeding PLC inputs, relay coils, or indicator lamps at different line voltages. The magnet coil connection uses a ring cable lug, which means the coil wires terminate with a crimped ring terminal under a screw — a robust connection that won't vibrate loose on a machine subject to continuous cycling.

This flexibility helps when you're fitting it into a tight corner of the enclosure or aligning it with existing busbars. These are the minimum air gaps to maintain for heat dissipation and arc flash clearance — ignore them and you risk derating or nuisance tripping in a warm cabinet. The storage range is wider because there's no current flowing and no heat to manage — useful to know if the contactor sits in an unheated warehouse before installation.

No broker or surplus channel needed.

MPN
3RT2023-4AP60