Siemens 3RV1421-0AA15

Siemens 3RV1421-0AA15 SIRIUS Circuit Breaker, Transformer Pr

MPN 3RV1421-0AA15

Siemens SIRIUS circuit breaker, 3RV1421-0AA15, for transformer protection, 0.16 A rated continuous current, 100 kA breaking capacity at 400 V AC, CLASS 10 trip, phase failure detection, screw terminals, 45 mm wide.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

3RV1421-0AA15 specifications
ParameterValue
Depth96 mm
Width45 mm
Height97 mm
Trip classCLASS 10

Product details

The CLASS 10 trip characteristic matches the inrush profile of small control transformers, so nuisance tripping on energization is minimized.

The 0.16 A continuous rating sets the maximum steady-state load without thermal trip. For a three-phase control transformer feeding a rectifier or multiple single-phase loads, this is a practical safeguard that a standard MCB won't give you. In a panel with a large upstream transformer or a stiff utility feed, that SCCR headroom keeps the breaker from becoming the weak link in the coordination study. Auxiliary contact ratings: 1 A at 24 V, 0.5 A at 230 V, 0.15 A at 60 V. These are the switching limits for the built-in auxiliary contacts — use them to signal the breaker's state to a PLC or annunciator. The 24 V rating covers the common control voltage in most panels; the 230 V rating lets you drive an indicator lamp directly without an interposing relay. Power loss of 5.5 W in hot operating state at AC.

The 45 mm width occupies one standard modular unit, so it fits alongside MCBs and contactors in a conventional DIN-rail layout. Dimensions: 45 mm wide, 97 mm high, 96 mm deep. The 96 mm depth is the front-to-back footprint — verify clearance behind the DIN rail, especially if the panel has a back plate or a rear wiring duct. Wire cross-sections: solid 2x (0.5...1.5 mm²) and 2x (0.75...2.5 mm²); stranded 2x (1...2.5 mm²) and 2x (2.5...6 mm²). AWG for main contacts: 2x (14...10). These cover the typical control wiring sizes — no need for ferrule adapters on stranded wire up to 2.5 mm².

The storage range exceeds the operating range — that's the handling limit, not the running limit. Shock resistance 25g / 11 ms, adequate for most industrial machinery and conveyor applications. Substance prohibitance date 01.05.2012 — this is the RoHS compliance cutoff. The part meets the RoHS directive as of that date, so it's acceptable for EU-market equipment and for customers with RoHS procurement requirements.

MPN