Skip to main content
Siemens 3RV2011-0DA25-ZX95

Siemens 3RV2011-0DA25-ZX95 SIRIUS Motor Protection CB, 0.32

MPN 3RV2011-0DA25-ZX95
Active

Siemens SIRIUS motor protection circuit breaker, 3RV2011-0DA25-ZX95, size S00, CLASS 10, 0.32 A, 100 kA breaking capacity, spring-type terminals, with transverse auxiliary switches 1 NO + 1 NC.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

3RV2011-0DA25-ZX95 specifications
ParameterValue
Trip classCLASS 10

Product details

Motor protection circuit breaker for the 0.32 A motor line

The Siemens SIRIUS 3RV2011-0DA25-ZX95 is a motor protection circuit breaker in the S00 frame, sized for a 0.32 A operational current with a CLASS 10 overload trip curve. The instantaneous short-circuit release is fixed at 4.2 A. Breaking capacity is a flat 100 kA across the entire voltage range from 240 V to 690 V AC — that covers virtually any industrial fault level you'll encounter in a 400 V or 480 V distribution panel without needing upstream current-limiting fuses. The unit ships with a factory-fitted transverse auxiliary switch block providing 1 NO + 1 NC contact for remote status feedback.

Sourcing and lifecycle — active production, quoted to order

The RoHS compliance date is 10 January 2009.

Panel integration — S00 footprint, DIN rail, spring terminals

The spring terminals accept 0.5–4 mm² conductors — no ferrule needed for stranded, but a 3 mm screwdriver shaft is specified for the release mechanism. Side-by-side mounting requires 30 mm clearance to adjacent devices on each side for thermal derating — zero clearance is allowed only with side-by-side mounting of identical S00 breakers. The unit dissipates 5.5 W at rated load in hot operating state.

How this compares to the screw-terminal sibling 3RV2011-0BA20

The closest functional peer is the 3RV2011-0BA20, which shares the same S00 frame, CLASS 10 trip, 100 kA breaking capacity, and 1 NO + 1 NC auxiliary configuration. The critical difference: the 3RV2011-0BA20 uses screw-type terminals and is rated at 0.2 A (adjustable 0.14–0.2 A), while the 3RV2011-0DA25-ZX95 uses spring-type terminals and is rated at 0.32 A (adjustable 0.22–0.32 A). If your BOM specifies the 0.2 A screw-terminal variant, the 0.32 A spring-terminal unit will not drop in without rewiring and re-setting the overload range — the terminal style and current range are different.

MPN
3RV2011-0DA25-ZX95