Siemens 3RW4435-6BC46

Siemens 3RW4435-6BC46 SIRIUS Soft Starter, 232 A at 40 °C

MPN 3RW4435-6BC46

Siemens SIRIUS 3RW4435-6BC46 soft starter, 232 A at 40 °C, 690 V insulation voltage, 50/60 Hz, screw fixing, 170 x 200 x 270 mm (W x H x D).

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

3RW4435-6BC46 specifications
ParameterValue
Mountingscrew fixing
Depth270 mm
Width170 mm
Height200 mm

Product details

232 A at 40 °C — current derating and load matching

The 3RW4435-6BC46: The 40 °C figure is the reference — if your panel ambient runs higher, the continuous current drops linearly; budget the actual load against the derated value, not the headline number. Inside-delta wiring is supported, which lets the soft starter handle roughly 58% of the motor FLA compared to in-line connection — useful for retrofitting into a panel where the existing contactor and overload are staying in the main circuit. Minimum load is 8% of the rated current — below that the thyristor firing angle may not hold conduction. Verify the motor no-load current exceeds this threshold, especially on small or lightly coupled loads.

Panel footprint and wiring terminals

Dimensions are 170 mm wide, 200 mm high, 270 mm deep — the depth is the dimension that drives enclosure depth selection. Main circuit termination accepts stranded 25–120 mm² or busbar connection; auxiliary contacts take solid 0.5–2.5 mm² or finely stranded 16–95 mm². The main lug range covers 4–250 kcmil — common for the 232 A class. Clearance at the side is 5 mm; upward clearance 100 mm, downward 75 mm — respect these for airflow and cable bending radius.

Protection and control features

Built-in motor overload protection and intrinsic device protection are included — no separate overload relay needed for most applications. Adjustable current limitation lets you set the starting current between 0 and the rated value, which helps on generators or weak supply networks. External reset input is present, so the soft starter can be reset from a remote pushbutton or PLC output without opening the panel door. Fault signal is displayed on the unit — no separate display module required for basic diagnostics. Pollution degree 3 per IEC 60947-4-2 means it's rated for industrial environments with conductive pollution — no additional conformal coating needed in most panel conditions.

Insulation voltage rated 690 V, operating frequency 50/60 Hz, thyristor-based design. The maximum motor cable length is 500 m — beyond that, reflected wave effects on the motor winding should be evaluated.