Skip to main content
Siemens 3RW4436-2BC46

Siemens 3RW4436-2BC46 SIRIUS Soft Starter, 281 A, 690 V

MPN 3RW4436-2BC46

Siemens SIRIUS 3RW4436-2BC46 soft starter, 281 A at 40 °C, 690 V insulation voltage, inside-delta circuit, 50/60 Hz, IP00, screw fixing.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

3RW4436-2BC46 specifications
ParameterValue
Mountingscrew fixing
Depth270 mm
Width170 mm
Height200 mm

Product details

281 A at 40 °C — derating drives the real limit

The 3RW4436-2BC46: If the panel ambient runs above 40 °C, the continuous current ceiling drops — size the upstream protection and cabling for the derated figure, not the 40 °C number. Insulation voltage rated 690 V, so it comfortably handles 400/480 V systems with margin. Operating frequency 50…60 Hz — one part covers both line standards.

Inside-delta circuit — line current savings

Thyristor-based with inside-delta wiring. In an inside-delta configuration the soft starter connects in series with each motor winding rather than the supply lines, reducing the line current draw by roughly 42 % compared to a standard in-line connection. This lets a lower-rated starter handle the same motor — check the motor nameplate FLA and winding configuration before specifying. Adjustable current limitation and integrated motor overload protection reduce external component count in the panel. Pollution degree 3 per IEC 60947-4-2 means it's rated for industrial environments with conductive dust — no additional derating needed for typical factory-floor air.

Panel fit — 200 x 170 x 270 mm, screw fixing

Dimensions 200 mm height, 170 mm width, 270 mm depth. Fastened with screw fixing; mounting position allows vertical surface with ±90° rotation and ±22.5° tilt front/back — useful for tight enclosures where the backplane angle is non-ideal. Main circuit connection via busbar or stranded cable 25…120 mm², finely stranded 16…95 mm², or kcmil 4…250. Auxiliary contacts accept 2x (24…16) AWG. Clearance: 100 mm upwards, 75 mm downwards, 5 mm at the side — plan the enclosure layout accordingly.

Fault indication and reset

External reset input and a display for fault signal — the display shows the fault code directly on the unit, so you don't need a laptop to read the trip cause. Wire length maximum 500 m for remote start/stop signals.

MPN