Siemens 3RW4446-2BC44

Siemens 3RW4446-2BC44 SIRIUS Soft Starter, 617A, 230V

MPN 3RW4446-2BC44

Siemens SIRIUS 3RW4446-2BC44 soft starter, 617 A at 40 °C, 230 V AC, 50/60 Hz, thyristor-based, inside-delta circuit, screw fixing, 298 x 210 x 230 mm.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

3RW4446-2BC44 specifications
ParameterValue
Mountingscrew fixing
Depth298 mm
Width210 mm
Height230 mm

Product details

Current rating and thermal derating

The 3RW4446-2BC44: The thyristor-based output handles the full motor start cycle without mechanical contacts, and the inside-delta wiring option reduces line current by 58 % compared to standard in-line connection — useful for retrofitting into existing cable runs without upsizing the supply feeder. Minimum load is 8 % of the rated current — below that the soft starter may not trigger reliably, so confirm the motor magnetising current exceeds this floor before committing the BOM line.

Mounting, clearance, and wiring constraints

Envelope is 298 mm deep, 210 mm wide, 230 mm high — screw-fixing to the back panel, not DIN-rail snap-on, so factor in drill-and-tap or through-hole mounting during panel layout. Clearance requirements: 100 mm above, 75 mm below, 5 mm at the sides — the vertical gap is the main space driver; stacking multiple units in a row needs the full 100 mm top clearance for airflow and service access. Main circuit connection is busbar only — no cable lugs on the power terminals. Stranded cable range is 70 to 240 mm² (or 2/0 to 500 kcmil using both clamping points), with the front clamp accepting up to 600 kcmil and the back clamp 250 to 500 kcmil. Mounting position is flexible: vertical surface with ±90° rotation and ±22.5° tilt forward/backward — useful for tight enclosures where the unit must be angled to clear gland plates or busbars.

Protection, control, and environment

Motor overload protection and intrinsic device protection are built in — no separate overload relay needed for the soft starter itself. Adjustable current limitation lets you set the start current between the minimum load threshold and the unit's full rating. External reset input and a fault-signal display (text/graphic, not just LEDs) simplify remote diagnostics — the display shows the fault code directly, which speeds troubleshooting on a line-down call. Operating temperature limit is 60 °C during operation; storage range is -25 to +80 °C. The derating temperature threshold is 40 °C — above that, use the derating curves in the manual, not the nameplate rating.

MPN
3RW4446-2BC44