Siemens 3RW4446-2BC44 SIRIUS Soft Starter, 617A, 230V

MPN3RW4446-2BC44

Siemens SIRIUS 3RW4446-2BC44 soft starter, 617 A at 40 °C, 230 V AC, 50/60 Hz, thyristor-based, inside-delta circuit, screw fixing, 298 x 210 x 230 mm.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

3RW4446-2BC44 — Identification
ParameterValue
Product designationSoft starter
Product brand nameSIRIUS
3RW4446-2BC44 — Power & Motor Rating
ParameterValue
Rated operational current at 40 °C617A
Rated operational current at 50 °C546A
Rated operational current at 60 °C485A
Rated insulation voltage690V
Minimum settable current (% of Ie)8%
3RW4446-2BC44 — Control & Connection
ParameterValue
Control supply voltage typeAC
Rated voltage at 50 Hz230V
Rated voltage at 60 Hz230V
Main circuit terminal typebusbar connection
Auxiliary contact rating (UL)B300 / R300
Control supply voltage tolerance, AC 50 Hz (max.)10%
Control supply voltage tolerance, AC 50 Hz (min.)-15%
Control supply voltage tolerance, AC 60 Hz (max.)10%
Control supply voltage tolerance, AC 60 Hz (min.)-15%
Control supply frequency tolerance (max.)10%
Control supply frequency tolerance (min.)-10%
Operating frequency tolerance (max.)10%
Operating frequency tolerance (min.)-10%
Operating voltage tolerance, inside-delta (max.)10%
Operating voltage tolerance, inside-delta (min.)-15%
3RW4446-2BC44 — Protection & Features
ParameterValue
Motor overload protectionYes
Thermistor motor protectionYes
Adjustable current limitationYes
Inside-delta connectionYes
Intrinsic device protectionYes
Pollution degree3, acc. to IEC 60947-4-2
3RW4446-2BC44 — Mechanical
ParameterValue
Height230mm
Width210mm
Depth298mm
Mounting positionwith vertical mounting surface +/-90° rotatable, with vertical mounting surface +/- 22.5° tiltable to the front and back
Fastening methodscrew fixing
Mounting clearance, top100mm
Mounting clearance, bottom75mm
Mounting clearance, side5mm
3RW4446-2BC44 — Environmental
ParameterValue
Operating temperature range60°C
Ambient class during operation (IEC 60721)3K6 (no formation of ice, no condensation), 3C3 (no salt mist), 3S2 (sand must not get into the devices), 3M6
Ambient class during transport (IEC 60721)2K2, 2C1, 2S1, 2M2 (max. fall height 0.3 m)

Product details

Current rating and thermal derating

The 3RW4446-2BC44: The thyristor-based output handles the full motor start cycle without mechanical contacts, and the inside-delta wiring option reduces line current by 58 % compared to standard in-line connection — useful for retrofitting into existing cable runs without upsizing the supply feeder. Minimum load is 8 % of the rated current — below that the soft starter may not trigger reliably, so confirm the motor magnetising current exceeds this floor before committing the BOM line.

Mounting, clearance, and wiring constraints

Envelope is 298 mm deep, 210 mm wide, 230 mm high — screw-fixing to the back panel, not DIN-rail snap-on, so factor in drill-and-tap or through-hole mounting during panel layout. Clearance requirements: 100 mm above, 75 mm below, 5 mm at the sides — the vertical gap is the main space driver; stacking multiple units in a row needs the full 100 mm top clearance for airflow and service access. Main circuit connection is busbar only — no cable lugs on the power terminals. Stranded cable range is 70 to 240 mm² (or 2/0 to 500 kcmil using both clamping points), with the front clamp accepting up to 600 kcmil and the back clamp 250 to 500 kcmil. Mounting position is flexible: vertical surface with ±90° rotation and ±22.5° tilt forward/backward — useful for tight enclosures where the unit must be angled to clear gland plates or busbars.

Protection, control, and environment

Motor overload protection and intrinsic device protection are built in — no separate overload relay needed for the soft starter itself. Adjustable current limitation lets you set the start current between the minimum load threshold and the unit's full rating. External reset input and a fault-signal display (text/graphic, not just LEDs) simplify remote diagnostics — the display shows the fault code directly, which speeds troubleshooting on a line-down call. Operating temperature limit is 60 °C during operation; storage range is -25 to +80 °C. The derating temperature threshold is 40 °C — above that, use the derating curves in the manual, not the nameplate rating.

Frequently asked questions

What is the current rating of 3RW4446-2BC44 at different ambient temperatures?

Rated 617 A at 40 °C, derated to 546 A at 50 °C, and 485 A at 60 °C. The 40 °C figure is the reference; above that, expect roughly 12 % reduction per 10 °C rise.

What clearance is needed around the 3RW4446-2BC44 in a panel?

100 mm above, 75 mm below, and 5 mm at the sides. The vertical clearance is the critical dimension for airflow and service access.

Does 3RW4446-2BC44 support inside-delta wiring?

Yes, the unit supports inside-delta circuit connection, which reduces line current by approximately 58 % compared to standard in-line wiring — useful when the supply cable is already sized for a lower current.

What compliance documentation is available for 3RW4446-2BC44?

The soft starter is designed to IEC 60947-4-2 (pollution degree 3). Standard Siemens documentation includes CE declaration of conformity and the product manual with installation, wiring, and parameterisation instructions. RoHS and REACH compliance is standard for current-production SIRIUS devices.

MPN
3RW4446-2BC44