Siemens 3RW4456-2BC45

Siemens 3RW4456-2BC45 SIRIUS Soft Starter, 1351 A at 40 °C

MPN 3RW4456-2BC45

Siemens SIRIUS 3RW4456-2BC45 soft starter, 1351 A at 40 °C, 690 V insulation voltage, 50/60 Hz, integrated bypass, inside-delta circuit, screw fixing, 510 x 640 x 290 mm.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

3RW4456-2BC45 specifications
ParameterValue
Mountingscrew fixing
Depth290 mm
Width510 mm
Height640 mm

Product details

Sizing the 3RW4456-2BC45 for the motor load

An integrated bypass contact system switches the thyristors out of the circuit once the motor is at speed, eliminating conduction losses and reducing heat load on the enclosure — the bypass also extends thyristor life by keeping them cool during run. The inside-delta wiring option lets the starter connect inside the motor delta winding, reducing the current per thyristor to 58 % of the line current — this is the standard configuration for large motors and halves the thermal stress on the power stack.

Mounting and wiring — panel integration constraints

Mounting position allows vertical surface with ±90° rotation and ±22.5° tilt forward/backward — the starter can be oriented to fit tight panel layouts, but the derating curve assumes vertical orientation; horizontal mounting may require additional airflow. Fastening is by screw fixing to the mounting surface — the 510 mm width, 640 mm height, and 290 mm depth require a backplate large enough to clear the enclosure door and allow cable bending radius below the starter.

Protection and control features for the commissioning engineer

Motor overload protection and intrinsic device protection are built in — the starter monitors motor current and internal thyristor temperature, tripping on overload or overtemperature without an external relay. Adjustable current limitation lets the commissioning engineer set the starting current between 8 % and 100 % of the rated motor current — the minimum load threshold is 8 %, so the starter can handle lightly loaded motors without nuisance tripping. A display for fault signals and external reset input allow remote fault acknowledgement and local diagnostics — the motor brake output controls a DC injection brake directly from the starter, eliminating a separate brake controller.

Pollution degree 3 per IEC 60947-4-2 means the starter is rated for conductive pollution in industrial atmospheres — no additional conformal coating required for most panel environments.

MPN
3RW4456-2BC45