Siemens 3RW5072-6AB15

Siemens 3RW5072-6AB15 Soft Starter, 90 A, 200-600 V, ATEX

MPN 3RW5072-6AB15
Active

Siemens 3RW5072-6AB15 soft starter, 90 A minimum rated current, 200-600 V operating voltage, Class 10A/10E/20E, ATEX, UKEX, IECEx, UL, CSA, 160 x 230 x 282 mm.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

3RW5072-6AB15 specifications
ParameterValue
Mountingscrew fixing
Depth282 mm
Width160 mm
Height230 mm
Trip classCLASS 10 A / 10E (preset) / 20E; acc. to IEC 60947-4-2
Service factor1
Digital output version2 normally-open contacts (NO) / 1 changeover contact (CO)

Product details

Trip class and motor protection

The 3RW5072-6AB15: Trip class is selectable between CLASS 10A, 10E (preset), and 20E per IEC 60947-4-2. CLASS 10A suits standard induction motors with short acceleration times; CLASS 20E handles high-inertia loads like centrifuges or crushers where the start current must be sustained longer without nuisance tripping. The minimum load setting is 15 % of the smallest settable Ie, which allows the soft starter to protect lightly loaded motors without false overcurrent trips. A service factor of 1 means no built-in overload margin beyond the set current — the trip threshold matches the motor FLA exactly.

Fieldbus and control integration

Onboard fieldbus options include PROFIBUS, Modbus RTU, Modbus TCP, and EtherNet/IP, plus PROFIenergy support when paired with the PROFINET communication module. This lets the starter participate in energy-management schedules and coordinated start sequences without a separate gateway. The analog output is configurable as 4-20 mA or 0-10 V (default 4-20 mA), parameterizable via the High Feature HMI. Remote reset is achieved by cycling the control supply voltage — no separate reset signal needed.

Mounting and thermal derating

Dimensions are 160 mm wide, 230 mm high, and 282 mm deep, with screw fixing to the mounting plate. Clearance requirements: 100 mm upward, 75 mm downward, 10 mm forward, 5 mm sideways, and 0 mm backward — the back can sit flush against the panel backplate. In a sealed enclosure with multiple drives, plan for forced ventilation or a larger cabinet to stay below the derating threshold.

Compliance and sourcing

No direct cross-reference to the alternate MPNs listed in the catalog — verify panel wiring before substituting.

MPN
3RW5072-6AB15