Siemens 3RW5114-1XC14

Siemens 3RW5114-1XC14 SIRIUS Soft Starter, 200-480 V

MPN 3RW5114-1XC14

Siemens SIRIUS 3RW5114-1XC14 soft starter, 200-480 V AC, Class 10A/10E/20E, screw-type control terminals, PROFIBUS/PROFINET/Modbus RTU, 321 x 185 x 203 mm.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

3RW5114-1XC14 specifications
ParameterValue
Mountingscrew fixing
Depth203 mm
Width185 mm
Height321 mm
Trip classCLASS 10 A (default) / 10E / 20E; acc. to IEC 60947-4-2
Service factor1
Digital output version2 normally-open contacts (NO) / 1 changeover contact (CO)

Product details

The 3RW5114-1XC14: For higher-inertia loads (centrifuges, crushers), switching to Class 20E gives a longer acceleration window before a trip. The unit supports both Voltage Ramp and Soft Torque starting profiles. Starting voltage is adjustable from 30-100 %; the stopping voltage is fixed at 50 %. Inside-delta connection is supported, which lets you size the soft starter for 58 % of the motor FLA when wired in the delta leg — a common panel trick to reduce unit cost on larger motors.

Fieldbus and HMI — no extra gateway needed

PROFIBUS DP, PROFINET IO, and Modbus RTU are all onboard — no external communication module required. The HMI-Standard and HMI-High Feature variants give you a local display for parameter readout and fault log access without a laptop. The analog output is configurable as 4-20 mA (default) or 0-10 V, so you can feed motor current or speed feedback straight to a PLC analog input or a panel meter.

Mounting and clearances for panel layout

Dimensions are 321 mm high, 185 mm wide, 203 mm deep. Mounting is by screw fixing; the unit can be tilted ±10° on a vertical surface. Minimum clearances around the unit: 100 mm above, 75 mm below, 10 mm in front, 5 mm at the sides, 0 mm at the rear. Plan the panel layout so the top vent isn't blocked by a busbar or another device.

Control wiring and diagnostics

Control connections use screw-type terminals — standard ferrule or ring-tongue. Remote reset is supported by cycling the control supply voltage off and on. The error logbook is stored internally, so when you power-cycle to clear a fault, the history stays. Auto-reset is also available if the application allows unattended restart after a trip.