Skip to main content
Siemens 3RW5213-3AC04

Siemens 3RW5213-3AC04 SIRIUS Soft Starter, 200-480 V

MPN 3RW5213-3AC04
Active

Siemens SIRIUS 3RW5213-3AC04 soft starter, 200-480 V rated voltage, minimum 5.5 A, Trip Class 10A/10E/20E per IEC 60947-4-2, PROFIBUS/Modbus RTU/Modbus TCP/EtherNet/IP/PROFINET, screw fixing, 275 x 170 x 152 mm.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

3RW5213-3AC04 specifications
ParameterValue
Mountingscrew fixing
Depth152 mm
Width170 mm
Height275 mm
Trip classCLASS 10 A (default) / 10E / 20E; acc. to IEC 60947-4-2
Service factor1

Product details

Trip class and motor protection logic

The 3RW5213-3AC04 is configured with Trip Class 10A as default, with selectable 10E and 20E classes per IEC 60947-4-2 — this determines the thermal overload curve the soft starter follows during a stall or jam condition. A minimum load threshold of 15 % relative to the smallest settable Ie means the soft starter will not attempt to regulate below that floor — useful when the downstream motor is oversized relative to the actual pump or fan load.

Supply voltage and ambient derating

Rated supply voltage spans 200 to 480 V AC, covering common 230/400/480 V industrial feeds without a tap-change transformer. The control supply is 24 V DC, which keeps the logic isolated from the power stage and allows a standard 24 V control transformer or UPS-backed bus to hold the soft starter in a known state during a voltage dip.

Fieldbus and communications integration

This SIRIUS soft starter carries PROFIBUS, Modbus RTU, Modbus TCP, EtherNet/IP, and PROFINET standard interfaces natively — no separate gateway module needed for most plant-floor networks. PROFIenergy is supported in connection with the PROFINET Standard communication module, which allows the drive to shed load during production pauses without cycling the main contactor. The analog output is configurable as 4-20 mA (default) or 0-10 V via the High Feature HMI, giving the DCS or PLC a real-time current or torque signal without a separate transducer.

Mechanical footprint and panel clearances

Dimensions are 275 mm height, 170 mm width, 152 mm depth — screw fixing to the back panel, not DIN rail, so the mounting plate must be drilled for the fixing centres. Required clearances: 100 mm upwards, 75 mm downwards, 10 mm forwards, 5 mm at the side, 0 mm backwards — the zero rear clearance means it can sit flush against the back panel, saving depth in a shallow enclosure.

Approvals and compliance documentation

CE marking, UL approval, and CSA approval are all confirmed on the record — the unit carries the marks needed for North American and European panel certification without a separate component-level review.

MPN
3RW5213-3AC04