Skip to main content
Siemens 3RW5534-6HA04

Siemens 3RW5534-6HA04 Soft Starter, 200-480 V, ATEX, Active

MPN 3RW5534-6HA04
Active

Siemens 3RW5534-6HA04 soft starter, 200-480 V rated, ATEX & IECEx certified, trip class 10A/10E/20E/30E, screw terminal, Modbus RTU/TCP, EtherNet/IP, active production.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

3RW5534-6HA04 specifications
ParameterValue
Mountingscrew fixing
Depth203 mm
Width185 mm
Height306 mm
Trip classCLASS 10 A / 10E (default) / 20E / 30E; acc. to IEC 60947-4-2
Service factor1.15

Product details

Soft starter for hazardous-area motor starting

The Siemens 3RW5534-6HA04 is a soft starter rated for 200-480 V supply, designed to ramp motors up and down smoothly while limiting inrush current. ATEX and IECEx certification allow installation in Zone 1/21 hazardous areas — the soft starter itself is not the ignition source, but the ATEX marking means it's assessed for use in explosive atmospheres per the equipment directive. Trip class is selectable: CLASS 10A / 10E (default) / 20E / 30E per IEC 60947-4-2, so you match the thermal overload protection to the motor start duty — 10A for normal starts, 30E for high-inertia loads.

Panel fit and thermal derating

The unit measures 306 mm high, 185 mm wide, 203 mm deep with a 100 mm clearance above and 75 mm below for airflow — plan the gland plate and DIN-rail layout accordingly. Side clearance is 5 mm; no rear clearance needed. Operating ambient is -25 to +60 °C, but derating applies at 40 °C or above — a panel builder should derate the continuous current above 40 °C per the manufacturer's curve, not just the nameplate rating.

Fieldbus and control flexibility

The soft starter integrates via Modbus RTU, Modbus TCP, EtherNet/IP, and PROFIBUS, with PROFIenergy support through PROFINET communication modules. An analog output configurable as 4-20 mA or 0-10 V feeds a remote SCADA or PLC analog input for motor current feedback. DC braking, pump ramp down, and a breakaway pulse handle specific load profiles — pump ramp down prevents water hammer on pump stops, breakaway pulse breaks stuck loads loose before ramping.

CE, UL, and CSA approvals cover European and North American installations. Accuracy Class 5 per IEC 61557-12 defines the measurement uncertainty for the integrated current/voltage metering — relevant for energy monitoring without a separate power meter. Service factor 1.15 means the soft starter can handle 115% of rated current continuously, matching typical motor service factors.

MPN
3RW5534-6HA04