Skip to main content
Siemens 4EU5021-0AC00

Siemens 4EU5021-0AC00 Commutating Choke, 617A 3-Phase 380V

MPN 4EU5021-0AC00

Siemens SENTRON 4EU5021-0AC00 commutating choke for converter, 3-phase, 380V AC, 617A rated current, 50Hz, IP00, Class H insulation, flat-type terminals.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

4EU5021-0AC00 specifications
ParameterValue
IP ratingIP00
Depth0.318 m
Width0.518 m
Height0.565 m

Product details

Commutating choke for converter duty

The Siemens 4EU5021-0AC00 is a 3-phase commutating choke (line reactor) rated for 617 A continuous at 380 V AC, 50 Hz. It is designed for converter input circuits where it limits di/dt, reduces harmonics, and protects the rectifier from line notching and commutation notches. The 0.00018 H inductance per phase and 15.62 % relative inductive voltage drop define its impedance — this is the figure that governs how much fault current the choke limits and how much voltage sag the DC link sees under load.

Rated 617 A AC continuous, the choke is sized for the input of a converter driving a motor load drawing roughly that line current — think a 315–355 kW drive on 400 V class supply. The DC rating of 756.1 A tells you the choke can handle the higher RMS current in DC-link applications if repurposed, but the primary role is AC line-side. The 1310 W coil loss and 345 W iron loss sum to about 1.65 kW of heat that must be ventilated out of the enclosure; IP00 means no ingress protection — the choke is an open-frame component that goes inside a panel or cabinet, never in a washdown or dusty zone. Class H insulation (180 °C rated) gives thermal headroom for the 40 °C ambient rating, so it can sit in a warm cabinet without derating.

Physical footprint and connections

Dimensions: 0.518 m wide × 0.565 m high × 0.318 m deep — a substantial block that needs a floor-mount or heavy shelf in the panel, not a DIN rail. Main circuit connections are flat-type terminals (bus-bar compatible), not screw clamps; plan for bolted copper bars or braided straps rated for the full 617 A. The three phases enter and exit on the same terminal plane, so layout the bus work accordingly.

MPN
4EU5021-0AC00