Skip to main content
Siemens 5SQ2270-2YA03

Siemens SENTRON 5SQ2270-2YA03 MCB, 2P C 3A, 400V AC

MPN 5SQ2270-2YA03

Siemens SENTRON 5SQ miniature circuit breaker, 5SQ2270-2YA03, 2-pole, C-curve, 3 A, 400 V AC, 3 kA per EN 60898, IP20.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

5SQ2270-2YA03 specifications
ParameterValue
Poles2
IP ratingIP20

Product details

Siemens SENTRON 5SQ2270-2YA03 — 2-pole C-curve MCB, 3 A, 400 V AC

The Siemens SENTRON 5SQ2270-2YA03 is a 2-pole miniature circuit breaker with a C tripping characteristic, rated at 3 A and 400 V AC at 50 Hz. It provides a breaking capacity of 3 kA per EN 60898, which is the standard for overcurrent protection in residential and commercial final circuits. This unit switches the neutral conductor (2-pole switching with neutral), a feature required for single-phase circuits where the neutral must be disconnected for full isolation. It fits into standard distribution boards on a DIN rail, occupying 2 width units (roughly 36 mm).

The C-curve characteristic (5–10× In) is chosen for circuits with a moderate inrush current — for example, a small compressor or a group of LED drivers — where a B-curve would nuisance-trip and a D-curve would allow too much energy through before opening. This is typical for final sub-circuits in a domestic or light commercial distribution board where the upstream fault level is limited. Overvoltage category 3 (rated impulse withstand voltage 4 kV) means it is suitable for fixed installations where the mains supply is not subject to direct lightning strikes. Energy limiting class 3 indicates the breaker limits the let-through energy (I²t) to a low level, reducing thermal stress on downstream wiring and equipment during a fault. This is a standard performance level for modern MCBs.

The 55 mm installation depth fits standard flush-mount distribution boards and enclosures with a 45 mm or 58 mm back-box depth. The snap-on DIN rail mounting allows tool-less installation and removal. The 2-pole width (2 width units) occupies the same footprint as a standard single-pole MCB pair, so it replaces an existing 2-pole breaker without re-spacing the DIN rail.

MPN
5SQ2270-2YA03