Siemens 5SQ2270-2YA03 — 2-Pole MCB (DIN Rail)

Siemens SENTRON 5SQ2270-2YA03 MCB, 2P C 3A, 400V AC

MPN5SQ2270-2YA03

Siemens SENTRON 5SQ miniature circuit breaker, 5SQ2270-2YA03, 2-pole, C-curve, 3 A, 400 V AC, 3 kA per EN 60898, IP20.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

5SQ2270-2YA03 — Identification
ParameterValue
Brand nameSENTRON
5SQ2270-2YA03 — Electrical
ParameterValue
Number of poles2
5SQ2270-2YA03 — Protection
ParameterValue
Tripping characteristic classC
Overvoltage category3
5SQ2270-2YA03 — Mechanical
ParameterValue
Installation depth55 mm
Protection degree (IP)IP20
5SQ2270-2YA03 — Other specifications
ParameterValue
Type of voltageAC/DC
Energy limiting class3
Number of width units2
Number of poles (Note)2P
Circuit-breaker (Design)5SQ
Current (at AC)3 A
Acc. to EN 60898 / rated value3 kA
Supply voltage (at AC)400 V
Supply voltage frequency50 Hz
Product function (neutral conductor switching)Yes

Product details

Siemens SENTRON 5SQ2270-2YA03 — 2-pole C-curve MCB, 3 A, 400 V AC

The Siemens SENTRON 5SQ2270-2YA03 is a 2-pole miniature circuit breaker with a C tripping characteristic, rated at 3 A and 400 V AC at 50 Hz. It provides a breaking capacity of 3 kA per EN 60898, which is the standard for overcurrent protection in residential and commercial final circuits. This unit switches the neutral conductor (2-pole switching with neutral), a feature required for single-phase circuits where the neutral must be disconnected for full isolation. It fits into standard distribution boards on a DIN rail, occupying 2 width units (roughly 36 mm).

The C-curve characteristic (5–10× In) is chosen for circuits with a moderate inrush current — for example, a small compressor or a group of LED drivers — where a B-curve would nuisance-trip and a D-curve would allow too much energy through before opening. This is typical for final sub-circuits in a domestic or light commercial distribution board where the upstream fault level is limited. Overvoltage category 3 (rated impulse withstand voltage 4 kV) means it is suitable for fixed installations where the mains supply is not subject to direct lightning strikes. Energy limiting class 3 indicates the breaker limits the let-through energy (I²t) to a low level, reducing thermal stress on downstream wiring and equipment during a fault. This is a standard performance level for modern MCBs.

The 55 mm installation depth fits standard flush-mount distribution boards and enclosures with a 45 mm or 58 mm back-box depth. The snap-on DIN rail mounting allows tool-less installation and removal. The 2-pole width (2 width units) occupies the same footprint as a standard single-pole MCB pair, so it replaces an existing 2-pole breaker without re-spacing the DIN rail.

Frequently asked questions

Will the 5SQ2270-2YA03 drop into a panel specified for the 5SQ2270-2YA04 without rewiring?

Yes, the two parts share the same 2-pole footprint, 55 mm depth, DIN rail mounting, and 2 width units. The only difference is the current rating: 3 A for the 5SQ2270-2YA03 versus 4 A for the 5SQ2270-2YA04. If the circuit load is 3 A or less, the 5SQ2270-2YA03 is a direct mechanical and electrical fit.

What is the number of poles on the 5SQ2270-2YA03?

It is a 2-pole (2P) breaker, switching both the line and neutral conductors.