Siemens 3RW4075-2BB34

Siemens 3RW4075-2BB34 SIRIUS Soft Starter, 356 A, 115 V coil

MPN 3RW4075-2BB34

Siemens SIRIUS 3RW4075-2BB34 soft starter, size S12, 356 A at 40 °C, 115 V coil 50/60 Hz, 3-phase, screw fixing, busbar connection.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

3RW4075-2BB34 specifications
ParameterValue
Mountingscrew fixing
Depth278 mm
Width160 mm
Height230 mm

Product details

Rated current and what it means for the motor

The 3RW4075-2BB34: That 40 °C figure is the baseline — above that, the thyristor junction temperature climbs and the output must be backed off. For a 315 A motor in a 50 °C panel, this starter lands right at the limit; for a 280 A motor at 60 °C, it's maxed out. The derating temperature is 40 °C, so if your enclosure runs hot, size up.

Mounting and connections — what fits in the panel

This is a size S12 frame — 230 mm high, 160 mm wide, 278 mm deep — fastened by screw fixing. The main current circuit uses busbar connection, accepting 2/0 to 500 kcmil at the back clamping point and 3/0 to 600 kcmil at the front. Stranded cable from 70 to 240 mm² or finely stranded 50 to 240 mm² fits the power terminals. Solid control wiring is 2x (0.25 to 1.5 mm²). Mounting position allows vertical surface with ±10° rotation without an additional fan; with the optional fan, ±90° rotation and ±22.5° tilt front/back.

Protection and control features

Built-in motor overload protection and intrinsic device protection are standard. Adjustable current limitation lets you set the starting current below the motor's locked-rotor draw — useful for soft starting conveyors or pumps where mechanical shock is a concern. Minimum load is 20 % of the rated current, so it won't regulate properly on a lightly loaded motor. External reset is available for remote restart after a fault. Pollution degree 3 per IEC 60947-4-2 means it's rated for industrial environments with conductive dust or humidity.

Coil voltage and operating conditions

Insulation voltage rated 600 V. Maximum motor cable length is 300 m — beyond that, capacitive charging current can cause nuisance trips or reduce starting torque. Not configurable for inside-delta connection.