Siemens 3RW4453-2BC45

Siemens 3RW4453-2BC45 SIRIUS Soft Starter, 954 A, 690 V

MPN 3RW4453-2BC45

Siemens SIRIUS 3RW4453-2BC45 soft starter, 954 A at 40 °C, 690 V insulation voltage, 50/60 Hz, with integrated bypass and adjustable current limitation.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

3RW4453-2BC45 specifications
ParameterValue
Mountingscrew fixing
Depth290 mm
Width510 mm
Height640 mm

Product details

954 A at 40 °C — derating curve matters for the panel build

The 3RW4453-2BC45: That derating slope means the panel ventilation and mounting position directly set the usable current — screw-fixed to a vertical surface, rotatable ±90° and tiltable ±22.5°, so you can orient it to pull cooler air across the heatsink. Insulation voltage rated 690 V, pollution degree 3 per IEC 60947-4-2, so it handles the typical 400–690 V industrial mains with margin for transient overvoltage in dirty environments.

Integrated bypass and inside-delta wiring

Built-in bypass contact system means the thyristors are shorted out once the motor is up to speed — no external bypass contactor needed, and the heat load in the panel drops to near zero during run. The inside-delta circuit option lets you wire the soft starter between the motor windings instead of in-line, reducing the current the unit sees by a factor of √3; useful for retrofitting into existing motor terminal boxes where cable routing is tight. Adjustable current limitation from 8% minimum load lets you dial in the start current to match the supply transformer capacity or generator set — set it just above the motor's no-load magnetizing current and the ramp is smooth without tripping upstream breakers.

Motor overload and intrinsic device protection onboard

Motor overload protection is integrated — no separate overload relay needed for the soft starter branch circuit. Intrinsic device protection monitors the thyristor junction temperature and shuts down before the semiconductor exceeds its SOA, which is the failure mode that takes out un-protected soft starters on a stalled-rotor start. External reset input and a display for fault signals mean the maintenance team gets a readable fault code without plugging in a laptop. The motor brake output component is built in, so a DC injection brake can be wired directly without an extra contactor.

Termination and wire sizing for the main circuit

Main current circuit termination is busbar connection — no lugs to crimp, just bolt the busbar directly. The stranded wire range is 70–240 mm², finely stranded 50–240 mm², and for North American builds it accepts 2/0–500 kcmil. Physical footprint: 510 mm wide, 640 mm high, 290 mm deep. Clearance requirements: 100 mm above, 75 mm below, 5 mm at the sides. Maximum motor cable length is 500 m — beyond that the cable capacitance can cause nuisance thyristor firing from leakage current.