Siemens 3RW4453-2BC45 — Soft Starters

Siemens 3RW4453-2BC45 SIRIUS Soft Starter, 954 A, 690 V

MPN3RW4453-2BC45

Siemens SIRIUS 3RW4453-2BC45 soft starter, 954 A at 40 °C, 690 V insulation voltage, 50/60 Hz, with integrated bypass and adjustable current limitation.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

3RW4453-2BC45 — Identification
ParameterValue
Product designationSoft starter
Product brand nameSIRIUS
3RW4453-2BC45 — Power & Motor Rating
ParameterValue
Rated operational current at 40 °C954A
Rated operational current at 50 °C856A
Rated operational current at 60 °C759A
Rated insulation voltage690V
Minimum settable current (% of Ie)8%
3RW4453-2BC45 — Control & Connection
ParameterValue
Control supply voltage typeAC
Rated voltage at 50 Hz230V
Rated voltage at 60 Hz230V
Main circuit terminal typebusbar connection
Auxiliary contact rating (UL)B300 / R300
Control supply voltage tolerance, AC 50 Hz (max.)10%
Control supply voltage tolerance, AC 50 Hz (min.)-15%
Control supply voltage tolerance, AC 60 Hz (max.)10%
Control supply voltage tolerance, AC 60 Hz (min.)-15%
Control supply frequency tolerance (max.)10%
Control supply frequency tolerance (min.)-10%
Operating frequency tolerance (max.)10%
Operating frequency tolerance (min.)-10%
Operating voltage tolerance, inside-delta (max.)10%
Operating voltage tolerance, inside-delta (min.)-15%
3RW4453-2BC45 — Protection & Features
ParameterValue
Motor overload protectionYes
Thermistor motor protectionYes
Adjustable current limitationYes
Inside-delta connectionYes
Intrinsic device protectionYes
Pollution degree3, acc. to IEC 60947-4-2
3RW4453-2BC45 — Mechanical
ParameterValue
Height640mm
Width510mm
Depth290mm
Mounting positionwith vertical mounting surface +/-90° rotatable, with vertical mounting surface +/- 22.5° tiltable to the front and back
Fastening methodscrew fixing
Mounting clearance, top100mm
Mounting clearance, bottom75mm
Mounting clearance, side5mm
3RW4453-2BC45 — Environmental
ParameterValue
Operating temperature range60°C
Ambient class during operation (IEC 60721)3K6 (no formation of ice, no condensation), 3C3 (no salt mist), 3S2 (sand must not get into the devices), 3M6
Ambient class during transport (IEC 60721)2K2, 2C1, 2S1, 2M2 (max. fall height 0.3 m)

Product details

954 A at 40 °C — derating curve matters for the panel build

The 3RW4453-2BC45: That derating slope means the panel ventilation and mounting position directly set the usable current — screw-fixed to a vertical surface, rotatable ±90° and tiltable ±22.5°, so you can orient it to pull cooler air across the heatsink. Insulation voltage rated 690 V, pollution degree 3 per IEC 60947-4-2, so it handles the typical 400–690 V industrial mains with margin for transient overvoltage in dirty environments.

Integrated bypass and inside-delta wiring

Built-in bypass contact system means the thyristors are shorted out once the motor is up to speed — no external bypass contactor needed, and the heat load in the panel drops to near zero during run. The inside-delta circuit option lets you wire the soft starter between the motor windings instead of in-line, reducing the current the unit sees by a factor of √3; useful for retrofitting into existing motor terminal boxes where cable routing is tight. Adjustable current limitation from 8% minimum load lets you dial in the start current to match the supply transformer capacity or generator set — set it just above the motor's no-load magnetizing current and the ramp is smooth without tripping upstream breakers.

Motor overload and intrinsic device protection onboard

Motor overload protection is integrated — no separate overload relay needed for the soft starter branch circuit. Intrinsic device protection monitors the thyristor junction temperature and shuts down before the semiconductor exceeds its SOA, which is the failure mode that takes out un-protected soft starters on a stalled-rotor start. External reset input and a display for fault signals mean the maintenance team gets a readable fault code without plugging in a laptop. The motor brake output component is built in, so a DC injection brake can be wired directly without an extra contactor.

Termination and wire sizing for the main circuit

Main current circuit termination is busbar connection — no lugs to crimp, just bolt the busbar directly. The stranded wire range is 70–240 mm², finely stranded 50–240 mm², and for North American builds it accepts 2/0–500 kcmil. Physical footprint: 510 mm wide, 640 mm high, 290 mm deep. Clearance requirements: 100 mm above, 75 mm below, 5 mm at the sides. Maximum motor cable length is 500 m — beyond that the cable capacitance can cause nuisance thyristor firing from leakage current.

Frequently asked questions

What is the 3RW4453-2BC45 rated current at different temperatures?

Rated 954 A at 40 °C, derating to 856 A at 50 °C and 759 A at 60 °C. The derating temperature threshold is 40 °C — above that, usable current drops linearly.

Does the 3RW4453-2BC45 include a bypass contactor?

Yes, the integrated bypass contact system is built in. Once the motor reaches full speed the thyristors are shorted out, so no external bypass contactor is required.

What wire sizes does the 3RW4453-2BC45 accept for the main power circuit?

Main circuit termination is busbar connection. Stranded wire range 70–240 mm², finely stranded 50–240 mm², and 2/0–500 kcmil for North American builds.

MPN
3RW4453-2BC45