Siemens 3RW4455-2BC35

Siemens 3RW4455-2BC35 SIRIUS Soft Starter, 1200A at 40°C

MPN 3RW4455-2BC35

Siemens SIRIUS 3RW4455-2BC35 soft starter, 1200 A at 40 °C, 690 V insulation voltage, 50/60 Hz, integrated bypass contact system, screw fixing.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

3RW4455-2BC35 specifications
ParameterValue
Mountingscrew fixing
Depth290 mm
Width510 mm
Height640 mm

Product details

Rated current and thermal derating

The 3RW4455-2BC35 delivers 1200 A at 40 °C ambient — this is the base rating for sizing the motor branch circuit. The derating temperature threshold is 40 °C; above that the thyristor junction temperature limits the output. For a pump or conveyor pulling 1000 A FLA in a 50 °C panel, this unit still has headroom — but at 60 °C the margin narrows to 46 A below the 1000 A mark.

Integrated bypass and inside-delta wiring

The integrated bypass contact system shorts the thyristors after the motor reaches full speed, eliminating SCR conduction losses during run. This means the heat sink sees only the start transient, not the full-load continuous dissipation — a meaningful advantage for panel fill factor and ventilation design. Inside-delta circuit capability allows the soft starter to be wired in the motor delta loop rather than the supply line, reducing the current through each SCR leg by roughly 42% compared to standard in-line connection. This is the wiring topology to use when the motor is delta-connected and the starter is sized for the phase current, not the line current.

Mounting dimensions and panel layout

Mounting position allows a vertical surface with +/-90° rotation and +/-22.5° tilt forward/back. Clearance requirements: 100 mm upward, 75 mm downward, 5 mm at the sides — the side gap is tight, so adjacent components must not block airflow across the heatsink fins.

Termination and wiring

Main current circuit termination is busbar connection — expect flat copper bars, not cable lugs, for the 1200 A path. The stranded wire range for the main circuit is 70–240 mm², finely stranded 50–240 mm², and AWG/kcmil 2/0–500.

Protection and control features

Motor overload protection and intrinsic device protection are built in — no separate overload relay needed in the motor branch circuit. Adjustable current limitation lets the starting current be set between 8% and 100% of the rated current, with a minimum load threshold of 8% below which the starter may not reliably detect the motor. A display for fault signals and external reset capability simplify troubleshooting on the line. The unit also includes a motor brake output component for applications requiring DC injection braking at stop.

Lifecycle and sourcing

For volume commitments or scheduled builds, confirm lead time and MOQ at quote.