Siemens 3RW4455-2BC35 — Soft Starters

Siemens 3RW4455-2BC35 SIRIUS Soft Starter, 1200A at 40°C

MPN3RW4455-2BC35

Siemens SIRIUS 3RW4455-2BC35 soft starter, 1200 A at 40 °C, 690 V insulation voltage, 50/60 Hz, integrated bypass contact system, screw fixing.

StockContact for availability
Lead timeIn Stock wk
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

3RW4455-2BC35 — Identification
ParameterValue
Product designationSoft starter
Product brand nameSIRIUS

Power & Motor Rating

3RW4455-2BC35 — Power & Motor Rating
ParameterValue
Rated operational current at 40 °C1 200A
Rated operational current at 50 °C1 065A
Rated operational current at 60 °C954A
Rated insulation voltage690V
Minimum settable current (% of Ie)8%

Control & Connection

3RW4455-2BC35 — Control & Connection
ParameterValue
Control supply voltage typeAC
Rated voltage at 50 Hz115V
Rated voltage at 60 Hz115V
Main circuit terminal typebusbar connection
Auxiliary contact rating (UL)B300 / R300
Control supply voltage tolerance, AC 50 Hz (max.)10%
Control supply voltage tolerance, AC 50 Hz (min.)-15%
Control supply voltage tolerance, AC 60 Hz (max.)10%
Control supply voltage tolerance, AC 60 Hz (min.)-15%
Control supply frequency tolerance (max.)10%
Control supply frequency tolerance (min.)-10%
Operating frequency tolerance (max.)10%
Operating frequency tolerance (min.)-10%
Operating voltage tolerance, inside-delta (max.)10%
Operating voltage tolerance, inside-delta (min.)-15%

Protection & Features

3RW4455-2BC35 — Protection & Features
ParameterValue
Motor overload protectionYes
Thermistor motor protectionYes
Adjustable current limitationYes
Inside-delta connectionYes
Intrinsic device protectionYes
Pollution degree3, acc. to IEC 60947-4-2

Mechanical

3RW4455-2BC35 — Mechanical
ParameterValue
Height640mm
Width510mm
Depth290mm
Mounting positionwith vertical mounting surface +/-90° rotatable, with vertical mounting surface +/- 22.5° tiltable to the front and back
Fastening methodscrew fixing
Mounting clearance, top100mm
Mounting clearance, bottom75mm
Mounting clearance, side5mm

Environmental

3RW4455-2BC35 — Environmental
ParameterValue
Operating temperature range60°C
Ambient class during operation (IEC 60721)3K6 (no formation of ice, no condensation), 3C3 (no salt mist), 3S2 (sand must not get into the devices), 3M6
Ambient class during transport (IEC 60721)2K2, 2C1, 2S1, 2M2 (max. fall height 0.3 m)

Product details

Rated current and thermal derating

The 3RW4455-2BC35 delivers 1200 A at 40 °C ambient — this is the base rating for sizing the motor branch circuit. The derating temperature threshold is 40 °C; above that the thyristor junction temperature limits the output. For a pump or conveyor pulling 1000 A FLA in a 50 °C panel, this unit still has headroom — but at 60 °C the margin narrows to 46 A below the 1000 A mark.

Integrated bypass and inside-delta wiring

The integrated bypass contact system shorts the thyristors after the motor reaches full speed, eliminating SCR conduction losses during run. This means the heat sink sees only the start transient, not the full-load continuous dissipation — a meaningful advantage for panel fill factor and ventilation design. Inside-delta circuit capability allows the soft starter to be wired in the motor delta loop rather than the supply line, reducing the current through each SCR leg by roughly 42% compared to standard in-line connection. This is the wiring topology to use when the motor is delta-connected and the starter is sized for the phase current, not the line current.

Mounting dimensions and panel layout

Mounting position allows a vertical surface with +/-90° rotation and +/-22.5° tilt forward/back. Clearance requirements: 100 mm upward, 75 mm downward, 5 mm at the sides — the side gap is tight, so adjacent components must not block airflow across the heatsink fins.

Termination and wiring

Main current circuit termination is busbar connection — expect flat copper bars, not cable lugs, for the 1200 A path. The stranded wire range for the main circuit is 70–240 mm², finely stranded 50–240 mm², and AWG/kcmil 2/0–500.

Protection and control features

Motor overload protection and intrinsic device protection are built in — no separate overload relay needed in the motor branch circuit. Adjustable current limitation lets the starting current be set between 8% and 100% of the rated current, with a minimum load threshold of 8% below which the starter may not reliably detect the motor. A display for fault signals and external reset capability simplify troubleshooting on the line. The unit also includes a motor brake output component for applications requiring DC injection braking at stop.

Lifecycle and sourcing

For volume commitments or scheduled builds, confirm lead time and MOQ at quote.

Frequently asked questions

What is the rated current of the 3RW4455-2BC35 at different temperatures?

At 40 °C the continuous rating is 1200 A. The derating temperature threshold is 40 °C.

How is the 3RW4455-2BC35 terminated for main power?

The main current circuit uses busbar connection. Stranded wire range is 70–240 mm², finely stranded 50–240 mm², and AWG/kcmil 2/0–500. Auxiliary and control circuits use spring-loaded terminals.

Does the 3RW4455-2BC35 include an integrated bypass?

Yes, it has an integrated bypass contact system that shorts the thyristors after the motor reaches full speed, eliminating SCR conduction losses during run. It also supports inside-delta circuit wiring.

MPN
3RW4455-2BC35