Skip to main content
Siemens 3RW4466-2BC46

Siemens 3RW4466-2BC46 SIRIUS Soft Starter, 2103 A, 690 V

MPN 3RW4466-2BC46

Siemens SIRIUS 3RW4466-2BC46 soft starter, 2103 A at 40 °C, 690 V insulation voltage, 50/60 Hz, integrated bypass, inside-delta circuit, screw fixing, 575 x 780 x 292 mm (WxHxD).

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

3RW4466-2BC46 specifications
ParameterValue
Mountingscrew fixing
Depth292 mm
Width575 mm
Height780 mm

Product details

Continuous current at your panel ambient

The 3RW4466-2BC46: The headline rating is 2103 A at 40 °C. The derating starts at 40 °C, so the installation's ambient temperature inside the enclosure sets the usable current — not the catalogue maximum. Insulation voltage is 690 V, and the operating frequency covers 50 to 60 Hz — suitable for global line supplies without a frequency derate.

Bypass, thyristors, and wiring topology

An integrated bypass contact system means the thyristors are shorted out after the start — the unit runs at near-zero forward drop in steady state, which eliminates the need to size the enclosure for continuous thyristor heat dissipation. Inside-delta wiring is supported, which lets the starter see phase-to-phase voltage rather than phase-to-neutral — this reduces the current per thyristor path and can allow a smaller frame for the same motor current.

Mounting, clearances, and termination

Screw fixing onto a vertical mounting surface; the unit can be rotated ±90° or tilted ±22.5° front/back. Minimum clearances: 100 mm above, 75 mm below, 5 mm at the sides. Main current circuit termination is busbar connection with a wire range of 70–240 mm² stranded or 50–240 mm² finely stranded, plus 2/0–500 kcmil.

Protection, control, and compliance

Motor overload protection and intrinsic device protection are built in, with adjustable current limitation. A display shows fault signals, and an external reset input allows remote clearing of trips. Pollution degree 3 per IEC 60947-4-2 — the starter is rated for industrial environments with conductive contamination. Maximum motor cable length is 500 m. Operating temperature range is 60 °C during operation, storage from -25 to +80 °C.

MPN
3RW4466-2BC46