Skip to main content
Siemens 3RW5076-2TB04

Siemens 3RW5076-2TB04 Soft Starter, 200 A, ATEX, 200-480 V

MPN 3RW5076-2TB04
Active

Siemens 3RW5076-2TB04 soft starter, 200 A minimum rated current, 200-480 V, ATEX Yes, IECEx Yes, Trip Class 10A/10E/20E, screw fixing, 282 mm depth, 160 mm width, 230 mm height.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

3RW5076-2TB04 specifications
ParameterValue
Mountingscrew fixing
Depth282 mm
Width160 mm
Height230 mm
Trip classCLASS 10 A / 10E (preset) / 20E; acc. to IEC 60947-4-2
Service factor1

Product details

What this soft starter delivers

The Siemens 3RW5076-2TB04 is a hybrid soft starter rated for a minimum motor current of 200 A at 200-480 V, with a Trip Class of 10A / 10E (preset) / 20E per IEC 60947-4-2. The 10A class means it clears a locked-rotor condition within 10 seconds at 7x FLA — tight enough for pump and conveyor starts where the motor must not cook during a stall. It carries ATEX and IECEx certification, so it's approved for installation in explosive atmospheres — Zone 1 or 21 gas/dust areas where a standard starter would be a hazard source. The ATEX marking on the nameplate is the ticket for the inspector. Fieldbus options include PROFIBUS, Modbus RTU, Modbus TCP, EtherNet/IP, and PROFINET, plus PROFIenergy support when paired with the PROFINET communication module. That gives the controls integrator a single cable for start/stop, ramp time, and fault log retrieval without pulling separate control wires.

Panel fit and mounting constraints

Mounts via screw fixing to a vertical surface, with ±90° rotation and ±22.5° tilt front-to-back. The 282 mm depth, 160 mm width, and 230 mm height mean it needs a backpanel clearance of at least 100 mm upwards, 75 mm downwards, 10 mm forwards, and 5 mm at the sides — plan the enclosure depth and cable entry accordingly. In a hot panel next to a drive, budget for the derate or add forced ventilation.

Approvals include CE, UL, and CSA — the UL and CSA marks cover North American installations without a separate evaluation. The ATEX and IECEx certificates are held by the manufacturer; request the certificate copy for the project documentation package.

MPN
3RW5076-2TB04