Siemens 3RW5236-2TC04

Siemens 3RW5236-2TC04 SIRIUS Soft Starter, 200-480 V

MPN 3RW5236-2TC04
Active

Siemens SIRIUS 3RW5236-2TC04 soft starter, 200-480 V rated voltage, 81 A minimum current, Class 10A/10E/20E trip class, PROFIBUS/Modbus RTU-TCP/EtherNet/IP/PROFINET, 306x185x203 mm, screw fixing.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

3RW5236-2TC04 specifications
ParameterValue
Mountingscrew fixing
Depth203 mm
Width185 mm
Height306 mm
Trip classCLASS 10 A (default) / 10E / 20E; acc. to IEC 60947-4-2
Service factor1
Digital output version2 normally-open contacts (NO) / 1 changeover contact (CO)

Product details

What voltage and current window does this soft starter cover?

The 3RW5236-2TC04: Rated for 200 to 480 V supply — covers common low-voltage three-phase networks across most industrial regions without a transformer tap. Minimum settable current is 81 A, meaning the soft starter can be configured down to that floor for smaller motors; the upper limit is set by the unit's full-load rating (not listed here, but the 81 A floor tells you this is a mid-range SIRIUS frame).

Fieldbus and control integration

Built-in PROFIBUS, Modbus RTU, Modbus TCP, EtherNet/IP, and PROFINET — no separate communication module needed for these five protocols, which covers the vast majority of PLC networks in European and North American plants. PROFIenergy support is present when paired with the PROFINET standard communication module, allowing the soft starter to participate in energy-management shut-down sequences during idle periods. Remote reset is possible by cycling the 24 V control supply — useful for unattended restart after a fault without a physical panel visit.

Mounting and environmental limits

Clearance requirements: 100 mm above, 75 mm below, 10 mm front, 5 mm sides, 0 mm rear — the tight rear clearance means it can sit flush against a backpanel, but the 100 mm top gap is non-negotiable for airflow and cable bend radius. Shock resistance is 15 g / 11 ms, dropping to 12 g / 11 ms if contact lifting is a concern — adequate for most industrial floor installations but not for shipboard or mobile equipment without additional damping.

Approvals and compliance documentation

Carries UL, CSA, and CE marking — accepted for panel builds destined for North America and the European Economic Area without additional agency review. Pollution degree 3 per IEC 60947-4-2 means it is rated for industrial environments with conductive pollution or dry non-conductive pollution that becomes conductive through condensation — standard for unsealed control cabinets.

MPN
3RW5236-2TC04