Siemens 3RW5236-2TC04 — Soft Starters

Siemens 3RW5236-2TC04 SIRIUS Soft Starter, 200-480 V

MPN3RW5236-2TC04
Active

Siemens SIRIUS 3RW5236-2TC04 soft starter, 200-480 V rated voltage, 81 A minimum current, Class 10A/10E/20E trip class, PROFIBUS/Modbus RTU-TCP/EtherNet/IP/PROFINET, 306x185x203 mm, screw fixing.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

3RW5236-2TC04 — Identification
ParameterValue
Product designationSoft starter
Product brand nameSIRIUS
3RW5236-2TC04 — Power & Motor Rating
ParameterValue
Rated motor power at 400 V (40 °C)90 kW
Rated motor power at 230 V (40 °C)45 kW
Rated operational current at 40 °C296 A
Rated operational current at 50 °C265 A
Rated operational current at 60 °C244 A
Rated insulation voltage600 V
Minimum settable current (% of Ie)15 %; Relative to smallest settable Ie
Power loss during startup (50 °C)2 037 W
3RW5236-2TC04 — Control & Connection
ParameterValue
Control supply voltage typeAC/DC
Rated voltage at 50 Hz24 V
Rated voltage at 60 Hz24 V
Main circuit terminal typebusbar connection
Control circuit wire range, solid2x (0.25 ... 1.5 mm²)
Control circuit wire range, finely stranded (with ferrule)2x (0.25 ... 1.5 mm²)
Analog outputNo
Auxiliary contact rated current, AC-15 at 250 V3 A
Auxiliary contact rating (UL)R300-B300
Control supply voltage tolerance, AC 50 Hz (max.)20 %
Control supply voltage tolerance, AC 50 Hz (min.)-20 %
Control supply voltage tolerance, AC 60 Hz (max.)20 %
Control supply voltage tolerance, AC 60 Hz (min.)-20 %
Control supply frequency tolerance (max.)10 %
Control supply frequency tolerance (min.)-10 %
Operating frequency tolerance (max.)10 %
Operating frequency tolerance (min.)-10 %
Operating voltage tolerance, inside-delta (max.)10 %
Operating voltage tolerance, inside-delta (min.)-15 %
3RW5236-2TC04 — Protection & Features
ParameterValue
Motor overload protectionYes; Full motor protection (thermistor motor protection and electronic motor overload protection)
Thermistor motor protectionYes; Type A PTC or Klixon / Thermoclick
Adjustable current limitationYes
Inside-delta connectionYes
Intrinsic device protectionYes
Pollution degree3, acc. to IEC 60947-4-2
3RW5236-2TC04 — Mechanical
ParameterValue
Height306 mm
Width185 mm
Depth203 mm
Weight7.15 kg
Mounting positionwith vertical mounting surface +/-90° rotatable, with vertical mounting surface +/- 22.5° tiltable to the front and back
Fastening methodscrew fixing
Mounting clearance, top100 mm
Mounting clearance, bottom75 mm
Mounting clearance, side5 mm
Mounting clearance, front10 mm
3RW5236-2TC04 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C; Please observe derating at temperatures of 40 °C or above
Storage / transport temperature range-40 ... +80 °C
Max. installation altitude5 000 m; Derating as of 1000 m, see catalog
Ambient class during operation (IEC 60721)3K6 (no ice formation, only occasional condensation), 3C3 (no salt mist), 3S2 (sand must not get into the devices), 3M6
Ambient class during transport (IEC 60721)2K2, 2C1, 2S1, 2M2 (max. fall height 0.3 m)
3RW5236-2TC04 — Specifications
ParameterValue
Trip ClassCLASS 10A (default) / 10E / 20E; acc. to IEC 60947-4-2
Number Of Controlled Phases3
Utilization category according to IEC 60947-4-2AC 53a
Product Feature Integrated Bypass Contact SystemYes
Start-Up Ramp Time Of Soft Starter0 ... 20 s
3RW5236-2TC04 — Electrical
ParameterValue
Current Limiting Value [%] Adjustable130 ... 700 %
Starting Voltage [%]30 ... 100 %
Stopping Voltage [%]50 %; non-adjustable

Product details

What voltage and current window does this soft starter cover?

The 3RW5236-2TC04: Rated for 200 to 480 V supply — covers common low-voltage three-phase networks across most industrial regions without a transformer tap. Minimum settable current is 81 A, meaning the soft starter can be configured down to that floor for smaller motors; the upper limit is set by the unit's full-load rating (not listed here, but the 81 A floor tells you this is a mid-range SIRIUS frame).

Fieldbus and control integration

Built-in PROFIBUS, Modbus RTU, Modbus TCP, EtherNet/IP, and PROFINET — no separate communication module needed for these five protocols, which covers the vast majority of PLC networks in European and North American plants. PROFIenergy support is present when paired with the PROFINET standard communication module, allowing the soft starter to participate in energy-management shut-down sequences during idle periods. Remote reset is possible by cycling the 24 V control supply — useful for unattended restart after a fault without a physical panel visit.

Mounting and environmental limits

Clearance requirements: 100 mm above, 75 mm below, 10 mm front, 5 mm sides, 0 mm rear — the tight rear clearance means it can sit flush against a backpanel, but the 100 mm top gap is non-negotiable for airflow and cable bend radius. Shock resistance is 15 g / 11 ms, dropping to 12 g / 11 ms if contact lifting is a concern — adequate for most industrial floor installations but not for shipboard or mobile equipment without additional damping.

Approvals and compliance documentation

Carries UL, CSA, and CE marking — accepted for panel builds destined for North America and the European Economic Area without additional agency review. Pollution degree 3 per IEC 60947-4-2 means it is rated for industrial environments with conductive pollution or dry non-conductive pollution that becomes conductive through condensation — standard for unsealed control cabinets.

Frequently asked questions

What is the 3RW5236-2TC04 used for?

It is a SIRIUS hybrid switching device — a soft starter — used to ramp three-phase induction motors up to speed gradually, reducing inrush current and mechanical shock on conveyors, pumps, fans, and compressors in industrial control panels.

Does the 3RW5236-2TC04 support pump ramp-down?

Yes, it includes a pump ramp-down function, which gradually reduces motor speed during stopping to prevent water hammer in pumping systems.

Can this soft starter be reset remotely?

Yes, remote reset is possible by turning off the 24 V control supply voltage — no physical button press required, which simplifies integration into automated restart sequences.