Skip to main content
Siemens 3RW5514-1HA14

Siemens 3RW5514-1HA14 Soft Starter, 200-480 V, ATEX

MPN 3RW5514-1HA14
Active

Siemens 3RW5514-1HA14 soft starter, 200-480 V rated voltage, ATEX and IECEx certified, trip class 10A/10E/20E/30E per IEC 60947-4-2, UL/CSA approved, 152 mm depth, 170 mm width, 275 mm height.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

3RW5514-1HA14 specifications
ParameterValue
Mountingscrew fixing
Depth152 mm
Width170 mm
Height275 mm
Trip classCLASS 10 A / 10E (default) / 20E / 30E; acc. to IEC 60947-4-2
Service factor1.15
Digital output version3 normally-open contacts (NO) / 1 changeover contact (CO)

Product details

Motor voltage and protection profile

The 3RW5514-1HA14: Rated operational voltage spans 200 to 480 V, covering standard low-voltage motor ratings across 50/60 Hz systems. Trip class is configurable as CLASS 10A / 10E (default) / 20E / 30E per IEC 60947-4-2, allowing the protection curve to match the motor thermal capacity and starting duty.

ATEX and IECEx certification for hazardous areas

Listed with ATEX and IECEx certification, this soft starter is approved for installation in explosive atmospheres where motor starting must not become an ignition source.

Fieldbus and control flexibility

Supports PROFIBUS, Modbus RTU, Modbus TCP, and EtherNet/IP, so it integrates into most automation architectures without a separate gateway. Analog output is configurable as 4-20 mA or 0-10 V, giving the PLC a direct process signal for current or torque monitoring.

Starting and stopping features for pump and conveyor duty

Voltage ramp, pump ramp down, and breakaway pulse are built in, so the same unit handles soft start, controlled deceleration on pumps, and high-breakaway-torque starts on conveyors. DC braking and motor heating functions are included for applications that need quick stops or anti-condensation heating during idle periods.

Panel fit and wiring

Dimensions are 152 mm depth, 170 mm width, and 275 mm height, with 100 mm clearance required above and 75 mm below for ventilation. Solid wire terminals accept 2x (1.0-2.5 mm²) and 2x (2.5-10 mm²) conductors, covering both control and power wiring in a single terminal block.

CE marked, UL approved, and CSA approved, so the unit meets European and North American regulatory requirements without additional certification steps.

MPN
3RW5514-1HA14