Siemens 3RW5514-3HA05

Siemens 3RW5514-3HA05 Soft Starter, 200-600 V, ATEX, IECEx

MPN 3RW5514-3HA05
Active

Siemens 3RW5514-3HA05 soft starter, 200-600 V rated voltage, ATEX and IECEx certified, Class 10A/10E/20E/30E trip class, PROFIBUS and Modbus TCP, 152 mm depth, 170 mm width, 275 mm height.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

3RW5514-3HA05 specifications
ParameterValue
Mountingscrew fixing
Depth152 mm
Width170 mm
Height275 mm
Trip classCLASS 10 A / 10E (default) / 20E / 30E; acc. to IEC 60947-4-2
Service factor1.15
Digital output version3 normally-open contacts (NO) / 1 changeover contact (CO)

Product details

Hazardous-area motor starting — ATEX and IECEx on the nameplate

The 3RW5514-3HA05: The rated voltage range of 200-600 V covers low-voltage networks globally, including 208 V, 400 V, and 480 V systems, without requiring a different unit for each voltage tier. Trip class selection from Class 10A through 30E (per IEC 60947-4-2) lets you match the thermal overload characteristic to the motor's starting duty — Class 10A for high-inertia loads that need a fast ramp, Class 30E for heavy starts with long acceleration times.

Fieldbus integration and analog feedback

PROFIBUS DP and Modbus TCP are both on board — no external gateway needed for either protocol, which simplifies the control-network topology and reduces the component count in the panel. The analog output is configurable as 4-20 mA or 0-10 V, so it can feed motor current, voltage, or power data directly to a PLC analog input or a local panel meter without a separate signal conditioner. PROFIenergy support (via PROFINET communication modules) allows the soft starter to participate in energy-management profiles, pausing the motor during idle periods and resuming on demand.

Mounting clearances and panel layout

Required clearances: 100 mm above, 75 mm below, 10 mm forward, 5 mm at the sides, and 0 mm behind — the zero rear clearance means it can sit flush against the back panel, saving depth in shallow enclosures. Solid wire connections accept 1.0-2.5 mm² and 2.5-10 mm² — the larger cross-section handles the main power wiring while the smaller terminals take control and signal cables.

Global approvals — UL, CSA, and CE marking — are all confirmed, meaning the unit is accepted in North American and European installations without additional certification work.

MPN
3RW5514-3HA05