Siemens 3RW5514-3HA05 — Soft Starters

Siemens 3RW5514-3HA05 Soft Starter, 200-600 V, ATEX, IECEx

MPN3RW5514-3HA05
Active

Siemens 3RW5514-3HA05 soft starter, 200-600 V rated voltage, ATEX and IECEx certified, Class 10A/10E/20E/30E trip class, PROFIBUS and Modbus TCP, 152 mm depth, 170 mm width, 275 mm height.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RW5514-3HA05 — Identification
ParameterValue
Product designationSoft starter
Product brand nameSIRIUS
3RW5514-3HA05 — Power & Motor Rating
ParameterValue
Rated motor power at 400 V (40 °C)7.5 kW
Rated motor power at 230 V (40 °C)4 kW
Rated operational current at 40 °C31.5 A
Rated operational current at 50 °C28 A
Rated operational current at 60 °C23.9 A
Rated insulation voltage600 V
Minimum settable current (% of Ie)10 %; Relative to set Ie
Power loss during startup (50 °C)229 W
3RW5514-3HA05 — Control & Connection
ParameterValue
Control supply voltage typeAC/DC
Rated voltage at 50 Hz24 V
Rated voltage at 60 Hz24 V
Main circuit terminal typescrew-type terminals
Control circuit wire range, solid2x (0.25 ... 1.5 mm²)
Control circuit wire range, finely stranded (with ferrule)2x (0.25 ... 1.5 mm²)
Analog outputYes; 4 ... 20 mA (default) / 0 ... 10 V
Auxiliary contact rated current, AC-15 at 250 V3 A
Auxiliary contact rating (UL)R300-B300
Control supply voltage tolerance, AC 50 Hz (max.)20 %
Control supply voltage tolerance, AC 50 Hz (min.)-20 %
Control supply voltage tolerance, AC 60 Hz (max.)20 %
Control supply voltage tolerance, AC 60 Hz (min.)-20 %
Control supply frequency tolerance (max.)10 %
Control supply frequency tolerance (min.)-10 %
Operating frequency tolerance (max.)10 %
Operating frequency tolerance (min.)-10 %
Operating voltage tolerance, inside-delta (max.)10 %
Operating voltage tolerance, inside-delta (min.)-15 %
3RW5514-3HA05 — Protection & Features
ParameterValue
Motor overload protectionYes; Full motor protection (thermistor motor protection and electronic motor overload protection) / When using the motor overload protection according to ATEX, an upstream contactor is required in inside-delta circuit.
Thermistor motor protectionYes; Type A PTC or Klixon / Thermoclick
Adjustable current limitationYes
Inside-delta connectionYes
Intrinsic device protectionYes
Pollution degree3, acc. to IEC 60947-4-2
3RW5514-3HA05 — Mechanical
ParameterValue
Height275 mm
Width170 mm
Depth152 mm
Weight2.3 kg
Mounting positionVertical (can be rotated +/- 90° and tilted forward or backward +/- 22.5°)
Fastening methodscrew fixing
Mounting clearance, top100 mm
Mounting clearance, bottom75 mm
Mounting clearance, side5 mm
Mounting clearance, front10 mm
3RW5514-3HA05 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C; Please observe derating at temperatures of 40 °C or above
Storage / transport temperature range-25 ... +80 °C
Max. installation altitude5 000 m; Derating as of 1000 m, see catalog
Ambient class during operation (IEC 60721)3K6 (no ice formation, only occasional condensation), 3C3 (no salt mist), 3S2 (sand must not get into the devices), 3M6
Ambient class during transport (IEC 60721)2K2, 2C1, 2S1, 2M2 (max. fall height 0.3 m)
3RW5514-3HA05 — Specifications
ParameterValue
Trip ClassCLASS 10A / 10E (default) / 20E / 30E; acc. to IEC 60947-4-2
Number Of Controlled Phases3
Utilization category according to IEC 60947-4-2AC 53a
Product Feature Integrated Bypass Contact SystemYes
Start-Up Ramp Time Of Soft Starter0 ... 360 s
Ramp-Down Time Of Soft Starter0 ... 360 s
3RW5514-3HA05 — Electrical
ParameterValue
Current Limiting Value [%] Adjustable125 ... 800 %
Starting Voltage [%]20 ... 100 %
Stopping Voltage [%]50 %; non-adjustable

Product details

Hazardous-area motor starting — ATEX and IECEx on the nameplate

The 3RW5514-3HA05: The rated voltage range of 200-600 V covers low-voltage networks globally, including 208 V, 400 V, and 480 V systems, without requiring a different unit for each voltage tier. Trip class selection from Class 10A through 30E (per IEC 60947-4-2) lets you match the thermal overload characteristic to the motor's starting duty — Class 10A for high-inertia loads that need a fast ramp, Class 30E for heavy starts with long acceleration times.

Fieldbus integration and analog feedback

PROFIBUS DP and Modbus TCP are both on board — no external gateway needed for either protocol, which simplifies the control-network topology and reduces the component count in the panel. The analog output is configurable as 4-20 mA or 0-10 V, so it can feed motor current, voltage, or power data directly to a PLC analog input or a local panel meter without a separate signal conditioner. PROFIenergy support (via PROFINET communication modules) allows the soft starter to participate in energy-management profiles, pausing the motor during idle periods and resuming on demand.

Mounting clearances and panel layout

Required clearances: 100 mm above, 75 mm below, 10 mm forward, 5 mm at the sides, and 0 mm behind — the zero rear clearance means it can sit flush against the back panel, saving depth in shallow enclosures. Solid wire connections accept 1.0-2.5 mm² and 2.5-10 mm² — the larger cross-section handles the main power wiring while the smaller terminals take control and signal cables.

Global approvals — UL, CSA, and CE marking — are all confirmed, meaning the unit is accepted in North American and European installations without additional certification work.

Frequently asked questions

What ATEX and IECEx certifications does the 3RW5514-3HA05 carry?

Both ATEX and IECEx certification are listed on the unit, qualifying it for installation in explosive atmospheres without additional protective systems.

What voltage range does the 3RW5514-3HA05 support?

The rated voltage is 200-600 V, covering common low-voltage networks worldwide including 208 V, 400 V, and 480 V systems.

What fieldbus protocols are built into the 3RW5514-3HA05?

PROFIBUS DP and Modbus TCP are both integrated — no external gateway needed for either protocol.