Skip to main content
Siemens 4EU3021-0AA10-0AA0

Siemens 4EU3021-0AA10-0AA0 Commutating Choke, 547A, 50Hz

MPN 4EU3021-0AA10-0AA0

Siemens SENTRON 4EU3021-0AA10-0AA0, commutating choke for converter, 3-phase, 290 V AC, 547 A max, 492.3 A rated, IP00, flat-type terminal.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

4EU3021-0AA10-0AA0 specifications
ParameterValue
IP ratingIP00
Depth0.211 m
Width0.3 m
Height0.269 m

Product details

What this choke is and where it runs

It carries a maximum continuous current of 547 A and a rated current of 492.3 A, with an inductance of 0.000025 H (25 µH) and a relative inductive voltage drop of 2.62% at rated conditions. That 2.62% drop is a typical value for a line reactor sized to limit harmonic distortion and di/dt stress on the converter's input rectifier — not a tuning choke for a drive output, but a line-side smoothing element.

Thermal and environmental limits

Thermal class H (IEC 60085) means the coil insulation withstands 180 °C hot-spot temperature — essential for a choke pulling 230 W of copper loss plus 80 W of iron-core loss at rated load. The ambient temperature rating of 40 °C is the reference; above that the current must be derated per the manufacturer's curve, which is typical for any IP00, open-frame reactor. IP00 means no ingress protection — this choke belongs in a clean, dry, ventilated enclosure, not on a washdown line or outdoors.

Physical fit and connection

Dimensions are 0.3 m wide × 0.269 m high × 0.211 m deep — roughly the footprint of a small suitcase. The main current circuit uses flat-type terminals (bus-bar or cable-lug connection), not screw-clamp or spring-cage. That means the panel builder needs to plan for bolted connections with appropriate lug size and torque, not a DIN-rail terminal block. The choke is not designed for snap-on DIN mounting; it is a chassis-mount or bolted-to-subplate component.

Standard compliance

The design follows EN 61558-2-20, the safety standard for small transformers and chokes. That covers dielectric strength, creepage distances, and thermal endurance. No UL or CSA listing is stated in the evidence, so for North American installs the integrator should verify local code acceptance or request the UL-recognized variant.

MPN
4EU3021-0AA10-0AA0