Siemens 5SY4206-6CC11 SENTRON MCB, 2P B 6A 10kA

MPN 5SY4206-6CC11

Siemens SENTRON miniature circuit breaker, 5SY4206-6CC11, 2-pole, B-curve, 6 A rated current, 10 kA breaking capacity at 400 V AC, 72 V DC max, IP20, active production.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

5SY4206-6CC11 specifications
ParameterValue
Poles2
IP ratingIP20
MountingQuick assembly system
Temp operating max75 °C
Temp operating min55 °C
Depth76 mm
Width36 mm
Height90 mm

Product details

What it is and where it fits

The Siemens 5SY4206-6CC11 is a SENTRON miniature circuit breaker — 2-pole, B-curve, rated 6 A at 400 V AC. It interrupts faults up to 10 kA per EN 60898, which means it clears short-circuits up to that level without welding contacts or cascading upstream in a panel. The B-curve trips between 3 and 5 times rated current, so it's sized for resistive and general-purpose loads where inrush stays moderate — think lighting circuits, control transformers, or relay banks. The 2-pole version switches both phase and neutral (or two phases) in one 36 mm wide module, saving a width unit over two singles. Rated for pollution degree 3 and overvoltage category III, this MCB handles the conductive environment inside an industrial enclosure. The IP20 rating with connected conductors is standard for a DIN-rail breaker.

Deployment context and ratings that matter

Snap it onto a 35 mm DIN rail inside the control panel — the quick-assembly system means no tools for mounting, just clip and wire. The combined terminal top and bottom accept solid or stranded copper; touch protection is built in, so live parts stay covered after wiring. The 70 mm installation depth leaves room behind the breaker for busbars or wiring ducts. Temperature derating applies: the breaker is rated for full 6 A up to 55 °C ambient, then linearly derated to 95 % at 55 °C, 55 % at 70 °C, and 35 % at 75 °C. The storage range is -40 °C to 75 °C. Designed for railway applications per the product designation. The halogen-free and silicon-free construction matters for panels where outgassing during a fault could contaminate sensitive electronics.