Skip to main content
Siemens 5SY4206-6CC11 — 2-Pole MCB (DIN Rail)

Siemens 5SY4206-6CC11 SENTRON MCB, 2P B 6A 10kA

MPN5SY4206-6CC11

Siemens SENTRON miniature circuit breaker, 5SY4206-6CC11, 2-pole, B-curve, 6 A rated current, 10 kA breaking capacity at 400 V AC, 72 V DC max, IP20, active production.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SY4206-6CC11 — Identification
ParameterValue
Product designationMiniature circuit breaker
Brand nameSENTRON
Application environmentMechanical engineering / industry
5SY4206-6CC11 — Electrical
ParameterValue
Number of poles2
5SY4206-6CC11 — Protection
ParameterValue
Tripping characteristic classB
Overvoltage categoryIII
5SY4206-6CC11 — Mechanical
ParameterValue
Width36 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Mounting positionany
Min.-40 °C
Max.75 °C
Protection degree (IP)IP20, with connected conductors
5SY4206-6CC11 — Environmental
ParameterValue
Pollution degree3

Product details

What it is and where it fits

The Siemens 5SY4206-6CC11 is a SENTRON miniature circuit breaker — 2-pole, B-curve, rated 6 A at 400 V AC. It interrupts faults up to 10 kA per EN 60898, which means it clears short-circuits up to that level without welding contacts or cascading upstream in a panel. The B-curve trips between 3 and 5 times rated current, so it's sized for resistive and general-purpose loads where inrush stays moderate — think lighting circuits, control transformers, or relay banks. The 2-pole version switches both phase and neutral (or two phases) in one 36 mm wide module, saving a width unit over two singles. Rated for pollution degree 3 and overvoltage category III, this MCB handles the conductive environment inside an industrial enclosure. The IP20 rating with connected conductors is standard for a DIN-rail breaker.

Deployment context and ratings that matter

Snap it onto a 35 mm DIN rail inside the control panel — the quick-assembly system means no tools for mounting, just clip and wire. The combined terminal top and bottom accept solid or stranded copper; touch protection is built in, so live parts stay covered after wiring. The 70 mm installation depth leaves room behind the breaker for busbars or wiring ducts. Temperature derating applies: the breaker is rated for full 6 A up to 55 °C ambient, then linearly derated to 95 % at 55 °C, 55 % at 70 °C, and 35 % at 75 °C. The storage range is -40 °C to 75 °C. Designed for railway applications per the product designation. The halogen-free and silicon-free construction matters for panels where outgassing during a fault could contaminate sensitive electronics.

MPN
5SY4206-6CC11