Skip to main content
ABB ACS580-01-03A5-4

ABB ACS580-01-03A5-4 Drive, 480V, 2 Hp, R1

MPN ACS580-01-03A5-4

ABB ACS580-01-03A5-4 general purpose drive, 3-phase, 480 V AC, 2 Hp normal duty / 1.5 Hp heavy duty, R1 frame wall-mount NEMA 1 enclosure.

$1,272.54 Ref. price · indicative, final on quote
Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

ACS580-01-03A5-4 specifications
ParameterValue
Product typeGeneral Purpose Drive
Horsepower2 hp
Phases3-phase

Product details

The ABB ACS580-01-03A5-4 is a general purpose drive in the ACS580 family, built for 3-phase operation at 480 V AC and rated 2 horsepower in the normal-duty profile. Mechanically it ships as a wall-mount drive in a NEMA 1 enclosure, frame size R1, with the published outline at H 14.69" × W 4.92" × D 8.78" — the small-cabinet footprint of the ACS580 series.

Read the duty pair, not the headline number

The spec carries two current and horsepower figures and the load profile is what picks between them: 4.8 A at 2 Hp on normal duty, 3.4 A at 1.5 Hp on heavy duty. For constant-torque loads — conveyors, positive-displacement pumps, mixers, extruders — the heavy-duty 3.4 A / 1.5 Hp figure is the one that governs the motor selection, and the normal-duty 4.8 A / 2 Hp number is additional headroom for variable-torque fans and centrifugal pumps. Supply-side input is specified across 380-480 V AC, three-phase, with a 3-phase output to the motor; a 480 V three-phase feeder is required on the line side.

Application fit at this frame

An R1-frame 480 V drive in the 1.5-2 Hp class is the typical pick for small industrial pumps, fans, blowers, and light conveyor duty where wall-mounting beside the motor disconnect keeps cable runs short. On cable length, the general rule with 480 V PWM output is to keep motor leads within the drive's published limit and add a dV/dt or sine filter on longer runs — reflected-wave voltage at the motor terminals can exceed insulation limits well before the drive itself flags a fault.

Sourcing posture

Sourcing is handled against an RFQ: quote to order on the BOM line rather than pulling from a generic shelf listing, and flag the exact duty profile (normal vs heavy) so the replacement matches the original application.

MPN
ACS580-01-03A5-4