Skip to main content
Siemens 3RW4046-1TB05

Siemens 3RW4046-1TB05 SIRIUS Soft Starter, 80 A at 40 °C

MPN 3RW4046-1TB05
Active

Siemens SIRIUS 3RW4046-1TB05 soft starter, Size S3, 80 A at 40 °C, 50/60 Hz, 600 V insulation, screw-type terminals, screw and snap-on mounting.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

3RW4046-1TB05 specifications
ParameterValue
Mountingscrew and snap-on mounting
Depth190 mm
Width70 mm
Height170 mm

Product details

80 A at 40 °C — the rating that governs the install

The 3RW4046-1TB05 is a SIRIUS soft starter from Siemens, Size S3 frame, designed to ramp three-phase induction motors up to 80 A at a 40 °C ambient. If the panel ambient runs above 40 °C, the 73 A or 66 A line is the one to budget against the motor FLA, not the headline 80 A. Rated insulation voltage is 600 V, operating frequency 50/60 Hz, and the pollution degree is 3 per IEC 60947-4-2 — meaning it's rated for the conductive-dust and condensation environment typical of industrial control panels.

Termination and wire range — what lands on the lugs

Main power connections use screw-type terminals. The main circuit accepts stranded wire 2 x (10 … 70 mm²) and finely stranded 2 x (10 … 50 mm²); the auxiliary contacts take 2 x (20 … 14 AWG). Solid wire for the control circuit is 2 x (0.5 … 2.5 mm²). That covers everything from a 4 AWG motor feed down to a 22 AWG start signal. Mounting is screw-and-snap-on to DIN rail. The envelope is 170 mm high, 70 mm wide, 190 mm deep. Clearance above the unit is 60 mm, below 40 mm, to the side 30 mm. With the optional fan, the mounting surface can be rotated ±90° or tilted ±22.5°; without the fan, rotation and tilt are limited to ±10°.

Protection and control — what's built in

Motor overload protection is integrated — no separate overload relay needed. Intrinsic device protection (thyristor overtemperature, phase imbalance, missing phase) is also on board. Adjustable current limitation lets you set the starting current between 20 % and the full rated current. An external reset input is provided. The maximum motor cable length is 300 m — relevant when the starter sits in a central MCC and the motor is at the far end of the line.

MPN