Siemens 3RW5521-3HA06

Siemens 3RW5521-3HA06 Soft Starter, 200-690 V, ATEX, Active

MPN 3RW5521-3HA06
Active

Siemens 3RW5521-3HA06 soft starter, 200-690 V rated voltage, ATEX and IECEx certified, trip class 10A/10E default, UL/CSA approved, active production.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

3RW5521-3HA06 specifications
ParameterValue
Mountingscrew fixing
Depth203 mm
Width185 mm
Height306 mm
Trip classCLASS 10 A / 10E (default) / 20E / 30E; acc. to IEC 60947-4-2
Service factor1.15

Product details

Rated voltage range and trip class selection

The 3RW5521-3HA06 is rated for 200 to 690 V, covering 208 V, 240 V, 400 V, 480 V, and 600 V nominal systems without a voltage tap change — one unit spans the low-voltage motor range common in North American and European installations. Trip class defaults to CLASS 10A or 10E per IEC 60947-4-2, with selectable 20E and 30E for higher-inertia loads. CLASS 10A limits the thermal overload to 10 seconds at locked-rotor current, protecting standard squirrel-cage motors during start; 20E or 30E extends the window for loads like centrifuges or crushers that need a longer acceleration ramp.

ATEX, IECEx, and North American approvals

ATEX and IECEx certification are listed on the unit, confirming compliance with explosive atmosphere directives for gas and dust groups — suitable for Zone 1/21 or Zone 2/22 installations per the equipment group and temperature class on the nameplate. UL and CSA approval are both present, so the soft starter is accepted in North American panels without additional agency review — a requirement for UL 508A listed assemblies.

Fieldbus connectivity and analog output

Modbus RTU, Modbus TCP, and EtherNet/IP are built in — no external gateway needed for these three protocols. PROFIBUS and PROFINET require optional communication modules; PROFIenergy is supported in conjunction with PROFINET High-Feature modules. The analog output is configurable as 4–20 mA or 0–10 V, defaulting to 4–20 mA, and can be mapped to motor current or load signal for SCADA trending without a separate current transformer.

Operating temperature and panel clearance

This affects enclosure sizing and ventilation design. Physical dimensions are 306 mm height, 185 mm width, and 203 mm depth. Clearance requirements: 100 mm above, 75 mm below, 10 mm forward, 5 mm at the sides, and 0 mm backward — the zero backward clearance allows flush mounting against a panel backplate, but the forward clearance must be maintained for wiring access and airflow.

MPN
3RW5521-3HA06