Skip to main content
Omron E2K-C25MY2-US — Proximity Sensors

Omron E2K-C25MY2-US 34mm Capacitive Sensor, 2-Wire AC NC

MPNE2K-C25MY2-US

Omron E2K-C25MY2-US, capacitive proximity sensor, 34 mm smooth barrel, unshielded, NC output, 2-wire AC 100–220 VAC, 2 m PVC cable, adjustable sensitivity.

$427.69Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

E2K-C25MY2-US — Electrical
ParameterValue
Supply voltage100 to 220 VAC
Connection / connectorPVC cable
E2K-C25MY2-US — Mechanical
ParameterValue
Size34 mm
Cable length2 m
E2K-C25MY2-US — Other specifications
ParameterValue
Output2 Wire AC
MountingBracket, 34 mm opening or sensor well
ShieldedUnshielded
OperationNC
Case materialHeat-resistant ABS
Overall lengthNon-threaded, 89mm length
Threaded lengthSmooth Barrel 34 mm dia.

Product details

E2K-C25MY2-US – 34 mm Capacitive Sensor with Adjustable Sensitivity

Smooth-barrel 34 mm capacitive sensor from Omron's E2K series, designed for non-contact detection of materials through non-metallic walls or bins. Adjustable sensitivity lets you set the range for specific targets — wood, plastic, liquid, grain. Unshielded construction: requires free space around the sensing face; cannot be mounted flush into metal. Wired normally closed, 2-wire AC, 100–220 VAC, with 2 m PVC cable. Drops into existing NC loops without rewiring. Mounting via bracket with 34 mm opening or sensor well. No threading — smooth barrel needs a clamp or compression fitting.

E2K-X8MY2 – Not a Mechanical Drop-In

The E2K-X8MY2 shares the same 2-wire AC NC output and supply voltage, but comes in an M18 threaded body with an 80 mm length and 40 mm threaded section. Electrical swap is straightforward — same wiring — but mechanical fit is incompatible. The 34 mm sensor needs a 34 mm opening; the M18 needs 18 mm. No adapter.

Sourcing

Its size and adjustable sensitivity make it a common spare for bin-level detection in food processing, packaging, and bulk-material handling.

Frequently asked questions

What is the supply voltage and output type?

100 to 220 VAC, 2-wire AC, normally closed.

Can this sensor be mounted flush?

No — unshielded construction requires free space around the sensing face; flush mounting in metal will cause false triggering.

Does the E2K-C25MY2-US replace the E2K-X8MY2?

Electrically yes, mechanically no. The 34 mm entry hole cannot accommodate an M18 body.

MPN