Skip to main content
Siemens 5SY5140-6CC11

SENTRON 5SY5140-6CC11 MCB, 1P B 40 A DC, 10 kA, Railway

MPN 5SY5140-6CC11

SENTRON 5SY5140-6CC11, 1-pole DC miniature circuit breaker, B-curve, 40 A rated current, 10 kA breaking capacity at 220 V DC per IEC 60947-2, designed for railway applications.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

5SY5140-6CC11 specifications
ParameterValue
Poles1
IP ratingIP20
MountingQuick assembly system
Temp operating max70 °C
Temp operating min-40 °C
Depth76 mm
Width18 mm
Height90 mm

Product details

Panel fit and wiring constraints

Width is 18 mm — one standard DIN-rail width unit — so it occupies a single slot on the rail. That 76 mm depth is the same as the 5SL3120-6MB peer, so if you're swapping into a panel built for that 5SL series, the envelope matches without re-drilling gland plates or re-routing cable bundles. Tightening torque is 2.5 to 3.5 N·m (22 to 31 lbf·in), which is typical for screw terminals on this class of breaker. Both top and bottom terminals are combined (line and load can land on either side), and the unit is sealable for tamper-proofing in metered or secured installations. Polarity must be observed on the DC supply — the datasheet notes 'Consider polarity' on the power supply connection.

The closest functional peer in the SENTRON family is the 5SL3120-6MB. Both are 1-pole, 18 mm wide, 76 mm deep, with B-curve tripping and IP20 touch protection. The critical difference: the 5SL3120-6MB is an AC-only breaker (rated 400 V AC, 4.5 kA per EN 60898), while the 5SY5140-6CC11 is a DC-rated universal-current breaker (220 V DC, 10 kA per IEC 60947-2). If your circuit is DC, the 5SL won't work — its DC breaking capacity is not specified. If your circuit is AC, the 5SY will still function (it's rated for 230/400 V AC as well per the description), but you're paying for the DC rating and railway qualification you may not need. Wire range on the 5SY goes up to 35 mm² solid/stranded; the 5SL tops out at 25 mm². Ambient temperature range is wider on the 5SY (-40 to +70 °C vs -25 to +45 °C). So if you're in a hot cabinet or cold outdoor location, the 5SY is the correct choice regardless of voltage type.

MPN