Skip to main content
Siemens 3RW4445-6BC34

Siemens 3RW4445-6BC34 SIRIUS Soft Starter, 542 A

MPN 3RW4445-6BC34

Siemens SIRIUS 3RW4445-6BC34 soft starter, 542 A at 40 °C, 690 V insulation voltage, 50/60 Hz, inside-delta circuit, thyristor-based.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

3RW4445-6BC34 specifications
ParameterValue
Mountingscrew fixing
Depth298 mm
Width210 mm
Height230 mm

Product details

542 A at 40 °C — the current ceiling that sets the motor match

The 3RW4445-6BC34 is rated 542 A at 40 °C ambient, which means it directly handles a motor full-load current up to that figure without external bypass contactors for the starting duty.

Inside-delta wiring and thyristor topology

This soft starter supports inside-delta circuit configuration, which reduces the current through each thyristor leg compared to standard in-line wiring — useful for larger motors where the line current would otherwise push the unit to a larger frame size. The thyristors handle the switching with no mechanical contacts, so the unit is rated for continuous starting duty without contact wear. Motor overload protection is integrated, so you do not need a separate overload relay in the motor branch circuit — the soft starter's own electronics handle the thermal model. Adjustable current limitation lets you tune the starting current between 8 % and the full rating, matching the load characteristic (conveyor, pump, fan) without changing hardware.

Mounting and connection flexibility for panel integration

Mounting position allows a vertical surface with ±90° rotation and ±22.5° tilt front-to-back — the unit can be oriented to fit tight enclosures or existing busbar layouts. Fastening is screw fixing, not DIN rail, so plan for direct panel mounting with four screws. Main circuit connections accept stranded wire 70–240 mm², finely stranded 50–240 mm², or kcmil 2/0–500, with busbar connection also listed. The auxiliary control wiring uses solid 0.5–2.5 mm² or stranded 20–14 AWG. Dimensions are 298 mm deep × 210 mm wide × 230 mm high — allow clearance: 100 mm above, 75 mm below, 5 mm at the sides for airflow and cable bending radius.

MPN
3RW4445-6BC34