Skip to main content
Siemens 6AG1212-1AE40-4XB0

Siemens 6AG1212-1AE40-4XB0 SIPLUS CPU 1212C, -40..70°C

MPN 6AG1212-1AE40-4XB0
Active

Siemens SIPLUS S7-1200, CPU 1212C, 6AG1212-1AE40-4XB0, extended temperature -40 to 70 °C, 24 V DC, 1 Mbyte work memory.

$735.46 Ref. price · indicative, final on quote
Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

6AG1212-1AE40-4XB0 specifications
ParameterValue
InterfacePROFINET
IP ratingIP20
AS-InterfaceYes
Temp operating max10 °C
Temp operating min-20 °C
Depth75 mm
Width90 mm
Height100 mm
Backup time480 h; Typical
Source sink inputYes
Conversion time per channel625 μs

Product details

Temperature-rated control for harsh environments

The Siemens 6AG1212-1AE40-4XB0 is the SIPLUS variant of the standard S7-1200 CPU 1212C, rated for -40 to 70 °C ambient. That range holds up to the steam and heat inside a tire-curing press enclosure where standard electronics degrade. It nails the cure recipe with the same 24 V DC supply and 1 Mbyte work memory as the base version, but tolerates the thermal cycling that kills ordinary controllers. Programmable in FBD, LAD, or SCL — pick the language that best matches the existing plant-standard logic. Three language options mean the line's control code can be maintained without retraining the electricians on a new paradigm. Integrated web server allows remote monitoring of input/output states and diagnostics over UDP/TCP. Forcing outputs is supported for commissioning stubs before the press is live.

Drop-in vs. the standard 6ES7212-1AE40-0XB0

Mechanical dimensions (100 × 90 × 75 mm) and 24 V DC power are identical to the standard CPU 1212C (6ES7212-1AE40-0XB0), so it slots into the same panel cutout and wiring loom. No rewiring or adapter plate needed. Rated for -40 to 70 °C ambient. Programming languages, I/O count, and PROFINET interface are shared between the two order codes. The only hardware add-on for legacy fieldbus is the CM 1243-5 PROFIBUS module, which both variants require.

75 mm depth leaves clearance for terminal blocks. PROFINET interface with autocrossing simplifies switchless line topologies. For existing PROFIBUS plants, order the CM 1243-5 separately — it occupies the left-side bus connector slot. Inputs accept 2-wire sensors; analog inputs handle 0 to +10 V. The PID controller block is built in, so no extra module for simple loop control on a steam valve.

MPN
6AG1212-1AE40-4XB0