A9R50225S — Residual Current Protection
ParameterValue
Earth-leakage sensitivity (IΔn)30 mA
Earth-leakage protection class / typeType AC
Earth-leakage trip time delayInstantaneous
Residual-current tripping technologyVoltage independent
A9R50225S — Electrical Ratings
ParameterValue
Rated current (In)25 A
Rated operational voltage (Ue)220...240 V AC 50/60 Hz
Poles description2P
Neutral pole positionLeft
Network typeAC
Network frequency50/60 Hz
Rated insulation voltage (Ui)440 V AC 50/60 Hz
Rated impulse withstand voltage (Uimp)4 kV
Device location in systemOutgoer
Electrical durabilityAC-1: 2000 cycles
Mechanical durability (operating cycles)5000 cycles
A9R50225S — Identification
ParameterValue
Product nameActi9 iID K
Product / component typeResidual current circuit breaker (RCCB)
Product range / familyActi9
Device short nameiID K
A9R50225S — Mechanical
ParameterValue
Mounting supportDIN rail
Mounting modeClip-on
Control typeToggle
Width in 9 mm modules4
Terminal connectionsTunnel type terminals top or bottom 1...35 mm² rigid Tunnel type terminals top or bottom 1...25 mm² flexible Tunnel type terminals top or bottom 1...25 mm² flexible with ferrule
Wire stripping length16 mm for top or bottom connection
Terminal tightening torque3.5 N.m top or bottom
Width36 mm
Height85 mm
Depth69 mm
A9R50225S — Environmental
ParameterValue
Operating ambient temperature-5...60 °C
Storage ambient temperature-40...85 °C
IP degree of protectionIP20 conforming to IEC 60529 IP40 (modular enclosure) conforming to IEC 60529
Pollution degree2
A9R50225S — Approvals
ParameterValue
StandardsEN/IEC 61008-1

Product details

The Schneider Electric A9R50225S is a 2-pole residual current circuit breaker (RCCB) from the Acti9 iID K series, rated 25 A with 30 mA earth-leakage sensitivity.

The 25 A rated current (In) sets the continuous load capacity — sized for branch circuits feeding lighting, socket outlets, or small equipment. The 30 mA sensitivity is the standard threshold for personal protection against lethal shock; Type AC detection means it trips on sinusoidal residual AC currents only, not pulsed or DC components, so it suits general-purpose circuits without electronic loads that generate smooth DC fault currents. Breaking capacity is rated Idm 500 A / Im 500 A, which covers most domestic and light commercial fault conditions. The instantaneous trip time (no intentional delay) ensures fast disconnection on earth faults. Voltage-independent residual current tripping means the RCCB detects leakage even if the line voltage drops — a reliability advantage for circuits with long cable runs or poor supply. IP20 (finger-safe) for the terminals; IP40 when housed in a modular enclosure. Ambient operating range is -5 to 60 °C; storage range -40 to 85 °C.

Designed and certified to EN/IEC 61008-1 (RCCB standard). Carries VDE quality label. Pollution degree 2 (normal, non-conductive pollution).

Frequently asked questions

What is the closest alternative to A9R50225S in the Acti9 family?

Within the Acti9 iID range, the primary difference between variants is the rated current (In) and sensitivity. The A9R50225S is a 25 A, 30 mA, 2P, Type AC unit. A higher-current sibling (e.g., 40 A) or a Type A variant (for pulsed DC-sensitive loads) would be the natural cross-reference — check the spec line for your circuit's load and fault-current profile.