A9R75225 — Residual Current Protection
ParameterValue
Earth-leakage sensitivity (IΔn)300 mA
Earth-leakage protection class / typeType AC
Earth-leakage trip time delayInstantaneous
Residual-current tripping technologyVoltage independent
A9R75225 — Electrical Ratings
ParameterValue
Rated current (In)25 A
Rated operational voltage (Ue)220...240 V AC 50/60 Hz
Poles description2P
Neutral pole positionLeft
Network typeAC
Network frequency50/60 Hz
Rated insulation voltage (Ui)440 V AC 50/60 Hz
Rated impulse withstand voltage (Uimp)4 kV
Device location in systemOutgoer
Electrical durabilityAC-1: 2000 cycles
Mechanical durability (operating cycles)5000 cycles
A9R75225 — Identification
ParameterValue
Product nameActi9 iID K
Product / component typeResidual current circuit breaker (RCCB)
Product range / familyActi9
Device short nameiID K
A9R75225 — Mechanical
ParameterValue
Mounting supportDIN rail
Mounting modeClip-on
Control typeToggle
Width in 9 mm modules4
Terminal connectionsTunnel type terminals top or bottom 1...35 mm² rigid Tunnel type terminals top or bottom 1...25 mm² flexible Tunnel type terminals top or bottom 1...25 mm² flexible with ferrule
Wire stripping length16 mm for top or bottom connection
Terminal tightening torque3.5 N.m top or bottom
Width36 mm
Height85 mm
Depth69 mm
A9R75225 — Environmental
ParameterValue
Operating ambient temperature-5...60 °C
Storage ambient temperature-40...85 °C
IP degree of protectionIP20 conforming to IEC 60529 IP40 (modular enclosure) conforming to IEC 60529
Pollution degree2
A9R75225 — Approvals
ParameterValue
StandardsEN/IEC 61008-1 EN/IEC 61008-2-1

Product details

The Schneider Electric A9R75225 is a 2-pole residual current circuit breaker (RCCB) from the Acti9 iID K series, rated 25 A with 300 mA earth-leakage sensitivity, Type AC, for 220-240 V AC networks at 50/60 Hz. 300 mA sensitivity covers fire risk from insulation faults on distribution subcircuits.

Rated 25 A continuous — sized for a 25 A outgoing feeder. 300 mA sensitivity, Type AC, detects sinusoidal AC residual currents only. Breaking capacity is rated Idm 500 A and Im 500 A — that's the short-circuit withstand at the device terminals, not a fault-clearing rating like an MCB. The RCCB relies on an upstream overcurrent protective device (MCB or fuse) to clear high faults; the 500 A rating means it survives that level without damage while the OCPD opens. Voltage-independent tripping means the residual current coil operates without needing a separate supply or neutral-to-earth voltage — it uses the fault current itself to trip, so it works even if the neutral is lost upstream.

Clip-on mounting to DIN rail, neutral on the left. Tunnel terminals accept 1-35 mm² rigid or 1-25 mm² flexible (with or without ferrule). Strip length 16 mm, torque to 3.5 N.m. That's a standard panel-building spec — no special tooling needed. IP20 on the body (finger-safe), IP40 inside a modular enclosure — fine for dry indoor distribution boards.