Skip to main content
Schneider Electric C063B3WM — Miniature Circuit Breakers (MCB)

C063B3WM ComPacT NS630bLB Basic Frame, 630A 3P Withdrawable,

MPNC063B3WM
Active

Schneider Electric ComPacT NS630b new generation, basic frame C063B3WM, 630 A at 50 °C, 3P, withdrawable, manually operated, 200 kA Icu at 415 V AC, IEC 60947-2.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

C063B3WM — Identification
ParameterValue
Product rangeComPacT
Product range (series)ComPacT NS630b...1600 new generation
Product/component typeBasic frame
Device applicationDistribution
C063B3WM — Ratings
ParameterValue
Rated current (In)630 A at 50 °C
Breaking capacity200 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 200 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 200 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 500/525 V AC 50/60 Hz conforming to IEC 60947-2 75 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
Rated service breaking capacity (Ics)200 kA at 220/240 V AC 50/60 Hz conforming to EN 60947-2 200 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 200 kA at 380/415 V AC 50/60 Hz conforming to EN 60947-2 75 kA at 660/690 V AC 50/60 Hz conforming to IEC 60947-2 100 kA at 500/525 V AC 50/60 Hz conforming to EN 60947-2
Rated operational voltage (Ue)690 V AC 50/60 Hz
Rated insulation voltage (Ui)800 V AC 50/60 Hz conforming to IEC 60947-2
Rated impulse withstand voltage (Uimp)8 kV conforming to IEC 60947-2
Network type (AC/DC)AC
Network frequency50/60 Hz
Utilisation categoryCategory A
Overvoltage categoryIII
C063B3WM — Protection
ParameterValue
Suitability for isolationYes conforming to EN/IEC 60947-2
Electrical durability (cycles)2000 cycles 690 V AC 50/60 Hz In conforming to IEC 60947-2 3000 cycles 690 V AC 50/60 Hz In/2 conforming to IEC 60947-2 3000 cycles 440 V AC 50/60 Hz In conforming to IEC 60947-2 4000 cycles 440 V AC 50/60 Hz In/2 conforming to IEC 60947-2
Mechanical durability (cycles)10000 cycles conforming to IEC 60947-2
C063B3WM — Mechanical
ParameterValue
Mounting supportBackplate
Mounting modeWithdrawable
Control typeManually operated
C063B3WM — Environmental
ParameterValue
Operating ambient temperature-25...70 °C
Storage ambient temperature-50...85 °C
IP degree of protectionIP40 conforming to IEC 60529
Pollution degree3 conforming to IEC 60947
C063B3WM — Approvals
ParameterValue
StandardsIEC 60947-2

Product details

The C063B3WM is a basic frame from the Schneider Electric ComPacT NS630b...1600 new generation range — a withdrawable, manually operated 3-pole chassis rated 630 A at 50 °C. It ships without a control unit or protection module (the 'without protection' designation), so it is a bare frame you fit with the appropriate trip unit for your distribution application. The 200 kA Icu at 380/415 V AC 50/60 Hz (IEC 60947-2) means it can interrupt fault currents up to that level without failing — critical for high-fault-capacity switchboards where a lower-rated frame would cascade upstream.

Breaking capacity and duty ratings

The LB breaking capacity code signals the high-end variant: 200 kA Icu at 220/240 V, 380/415 V, and 440 V AC; 100 kA at 500/525 V; 75 kA at 660/690 V. The 40 kA integral instant protection is a built-in magnetic trip threshold — the frame itself will open on a massive fault even without a control unit fitted.

The ComPacT NS630b new generation is the active platform.

Frequently asked questions

What is C063B3WM's breaking capacity at 415 V?

200 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2. The Ics service breaking capacity is also 200 kA at that voltage, so the frame remains usable after clearing a fault at that level.

What compliance documentation does Schneider provide for C063B3WM?

The frame is designed and tested to IEC 60947-2, with pollution degree 3, overvoltage category III, and suitability for isolation per EN/IEC 60947-2. For specific RoHS, REACH, or UL documentation, request the manufacturer's declaration at quote time.

MPN
C063B3WM