Schneider Electric C063L32AFM — Miniature Circuit Breakers (MCB)

Schneider Electric C063L32AFM ComPacT NS 630A 3P MCCB, 150kA

MPNC063L32AFM
Active

Schneider Electric ComPacT NS new generation, C063L32AFM, 3P fixed MCCB, 630 A, MicroLogic 2.0 A electronic trip unit, 150 kA Icu at 415 V AC, IP40.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

C063L32AFM — Identification
ParameterValue
Product nameComPacT NS new generation
Product rangeComPacT
Product range (series)ComPacT NS630b...1600 new generation
Product/component typeCircuit breaker
Device applicationDistribution
C063L32AFM — Ratings
ParameterValue
Rated current (In)630 A at 50 °C
Breaking capacity150 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 150 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 130 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 500/525 V AC 50/60 Hz conforming to IEC 60947-2
Rated service breaking capacity (Ics)150 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 150 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 130 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 100 kA at 500/525 V AC 50/60 Hz conforming to IEC 60947-2
Rated operational voltage (Ue)690 V AC 50/60 Hz
Rated insulation voltage (Ui)800 V AC 50/60 Hz conforming to IEC 60947-2
Rated impulse withstand voltage (Uimp)8 kV conforming to IEC 60947-2
Network type (AC/DC)AC
Network frequency50/60 Hz
Utilisation categoryCategory A
Overvoltage categoryIII
C063L32AFM — Protection
ParameterValue
Trip unit technologyElectronic
Earth-leakage protectionWithout
Suitability for isolationYes conforming to EN/IEC 60947-2
Electrical durability (cycles)2000 cycles at 690 V In 3000 cycles at 690 V In/2 3000 cycles at 440 V In 4000 cycles at 440 V In/2
Mechanical durability (cycles)10000 cycles
C063L32AFM — Mechanical
ParameterValue
Mounting supportBackplate
Mounting modeFixed
Control typeManually operated
Local signalling/indication4 LEDs (red) for fault indication 1 LED (yellow) for overload
C063L32AFM — Environmental
ParameterValue
Operating ambient temperature-25...70 °C
Storage ambient temperature-40...85 °C
IP degree of protectionIP40 conforming to IEC 60529
Pollution degree3 conforming to IEC 60947
Relative humidity0...95 %
C063L32AFM — Approvals
ParameterValue
StandardsEN/IEC 60947-2
C063L32AFM — Specifications
ParameterValue
[Ir] long-time protection pick-up adjustment range0.4...1 x In
Trip unit protection functionsLI

Product details

630 A distribution breaker with a 150 kA interrupting rating

The MicroLogic 2.0 A electronic trip unit gives you L (long-time overload) and I (instantaneous short-circuit) protection curves, with an ammeter readout on the LCD display for on-site load monitoring. Mechanical durability is 10,000 cycles, electrical durability ranges from 2,000 cycles at 690 V In up to 4,000 cycles at 440 V In/2 — this is a switch you can use for infrequent manual switching, not a contactor duty cycle. Fixed front-front connection with 70 mm pitch, backplate mount, IP40 enclosure. At 327 x 210 x 147 mm (H x W x D), it fills a standard MCC bucket or distribution panel cutout.

Still in current production — no replacement watch needed

This part carries a current lifecycle status from Schneider — no phase-out, no last-time-buy notice, no successor to track. It's an active catalog number in the ComPacT NS630b...1600 new generation range, so you can spec it into a BOM freeze without worrying about a PCN next quarter.

The electronic trip unit includes 20-minute thermal memory, so it remembers prior heating after a trip and re-closes with a shorter allowable cool-down — useful for motor starts or pulsed loads that heat the breaker between trips. The IK07 impact rating (EN 50102) handles a 2 J hammer blow, so it survives rough handling during panel assembly. Four red LEDs for fault indication and one yellow LED for overload give you a visual read without needing to connect a communication module. Altitude rating is 0–2000 m without derating, 2000–5000 m with derating — relevant if this goes into a high-altitude installation like a mine or mountain facility.

Frequently asked questions

What is the breaking capacity of C063L32AFM?

150 kA Icu at 380/415 V AC 50/60 Hz per IEC 60947-2, with 130 kA at 440 V and 100 kA at 500/525 V.

Where can I buy C063L32AFM?

Sourced and quoted to order against an RFQ through independent distribution channels; availability and current pricing confirmed at quote time.

What trip unit does C063L32AFM use?

MicroLogic 2.0 A electronic trip unit with L (long-time overload) and I (instantaneous short-circuit) protection, plus an integrated ammeter on the LCD display.

What standards does C063L32AFM comply with?

EN/IEC 60947-2 for low-voltage switchgear and controlgear, with pollution degree 3 and overvoltage category III.

MPN
C063L32AFM